Rockwell Automation FactoryTalk Transaction Manager User Guide User Manual

Page 88

Advertising
background image

FactoryTalk Transaction Manager User Guide

88

The following figure shows an example Data Object Definition dialog box
(click Step 4 on the Configuration Checklist).

Figure 11: Data Object Definition dialog box

The target database tables, views, and stored procedures must already exist
in the database to be used in data objects. You can also create new stored
procedures using the Stored Procedure Wizard (for Microsoft SQL Server
7.0 or later and Oracle only).

If you modify target database tables, views, or stored procedures in the database

after you create a data object within FactoryTalk Transaction Manager, you must
click Apply on the Data Object Definition dialog box so that data object recognizes
the database modifications.

Enterprise database connectors (ODBC, Oracle OCI, or Microsoft OLE DB)
can communicate with databases located on other computers. Multiple data