Q45VR3 Series Specifications

Supply Voltage and Current

Universal voltage: 24 to 250V ac, 50/60 Hz or 12 to 250V dc (1.5 watts maximum)

Supply Protection Circuitry

Protected against transient voltages. DC hookup is without regard to polarity.

Output Configuration

SPDT (Single-Pole, Double-Throw) electromechanical relay output. All models except emitters.

Output Rating

Max. switching power (resistive load): 1250VA, 150W
Max. switching voltage (resistive load): 250V ac, 125V dc
Max. switching current (resistive load): 5A @ 250V ac, 5A @ 30V dc derated to 200 mA @ 125V dc
Min. voltage and current: 5V dc, 10mA
Mechanical life of relay: 50,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations

Output Protection Circuitry

Protected against false pulse on power-up

Output Response Time

15 milliseconds ON and OFF
(NOTE: 100 millisecond delay on power-up. Relay is de-energized during this time.)

Repeatability

Opposed mode: 0.25 milliseconds
All other sensing modes: 0.5 milliseconds
Response time and repeatability specifications are independent of signal strength.

Adjustments

Light/Dark Operate select switch; and multi-turn Sensitivity control on top of sensor beneath a transparent
o-ring-sealed Lexan

®

cover, allows precise sensitivity setting (turn clockwise to increase gain). Optional logic

and logic/display modules have adjustable timing functions (see page 10).

Indicators

Indicator LEDs are clearly visible beneath a raised transparent Lexan

®

dome on top of the sensor.

Power (green) LED lights whenever 24 to 250V ac, or 12 to 250V dc power is applied
Signal (red) AID™ System LED lights whenever the sensor sees its modulated light source, and pulses at a
rate proportional to the strength of the received light signal
Load (yellow) LED lights whenever the output relay is energized
Optional 7-element LED signal strength display module

Construction

Molded reinforced thermoplastic polyester housing, o-ring-sealed transparent Lexan

®

cover, molded acrylic

lenses, and stainless steel hardware. Q45s are designed to withstand 1200 psi washdown. The base of
cabled models has a 1/2" NPS integral internal conduit thread.

Environmental Rating

NEMA 6P, IEC IP67

Connections

PVC-jacketed 2 m (6.5') or 9 m (30') unterminated cables, or Mini-style quick-disconnect (QD) fittings are
available (“Q”- suffix models). QD cables are ordered separately. See page 10.

Operating Conditions

Temperature: -25° to +55° C (-13° to +131°F)
Maximum relative humidity: 90% at 50°C (non-condensing)

Application Notes

Transient suppression is recommended for contacts switching inductive loads.
Optional output timing modules are available. See page 10 for more information.