Over-Height Detection Kit –

For BMHE Series Heated Enclosures

WARRANTY: Banner Engineering Corp. warrants its products to be free from
defects for one year. Banner Engineering Corp. will repair or replace, free of
charge, any product of its manufacture found to be defective at the time it is
returned to the factory during the warranty period. This warranty does not cover
damage or liability for the improper application of Banner products. This warranty
is in lieu of any other warranty either expressed or implied.

Assembly Directions

To reduce the risk of optical crosstalk, mount the Q40 emitter
above the light screen receiver, and the Q40 receiver above the
light screen emitter.

1. Route the user-supplied sensor cable into the heated

enclosure, allowing enough length to reach the top of the
enclosure; trim excess length. (Receivers require 4-wire
cable; emitters require only 2 wires.)

2. Strip the cable jacket 22-26 mm and the conductor wire

insulation 6 mm. Slide back shell components onto cable.

3. Loosen the screws in the connector terminals; insert the

wires as indicated in the hookup diagrams; tighten screws
to hold the wires in place. Connect the back shell
components. (The rear nut should be finger-tight.)

4. Assemble the sensor to the swivel bracket; attach the swivel

bracket to the stainless steel base bracket.

5. Slide a spring nut into each of the 2 heated enclosure

channels. Attach the stainless steel base bracket to the
enclosure, by attaching the two stainless steel 10-32
screws, lock washers and flat washers through the holes in
the bracket and into the spring nuts.

6. Attach the cable connector to the sensor QD connector.

Figure 2. Over-Height Detection Kit, shown assembled and ready

to install into heated enclosure

Hookups

Q40SN6RQ Receiver

Q406EQ Emitter

Standard Hookup

Alarm Hookup

NOTE: No connection to

connector pins 2 and 4.

3
1

-

+

4
2

Load

Load

Load

Load

10-30V dc

10-30V dc

3

1

-

+

4
2

Alarm

Load

1
3

-

+

4
2

10-30V dc

10-32 Spring Nut In

Heated Enclosure

Channel

#10 Stainless Steel

Lock Washer

#10 Stainless Steel

Flat Washer

10-32 x 1/2" SCHC

Stainless Steel

Advertising