0 Diagnostic Event Counter: This event is sent when ever a flag in attribute 9 is set. This event also sends one data

byte. This byte contains the value of attribute #8, the Diagnostic Error Counter. Typically, this event is sent as a result of

a low gain condition.
Write ON/OFF: These events are sent when the Cyclic Timer has expired. Either a WRITE ON or a WRITE OFF

special event is sent reflecting the state of the input. This event can be masked by clearing attribute 6.
Change Of State ON: When the output of the sensor transitions to the ON state this message is sent. This event can be

masked by clearing attribute 6.
Change Of State OFF: When the output of the sensor transitions to the OFF state this message is sent. This event can be

masked by clearing attribute 6.

Banner Engineering Corp. 9714 10th Ave. No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications): (612) 544-3573

WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or
replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty
does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.

EVENTS

Event Description

Output Data Parameters Output Data Parameter Type

0

Diagnostic Event Counter Counter Value

Unsigned 8

Write ON

None

Write OFF

None

Change of State ON

None

Change of State OFF