Banner S18 Series User Manual

S18 sensors – ac-voltage series, Features, Models

Advertising
background image

Printed in USA

01/05

P/N 121521

S18 Sensors – ac-Voltage Series

Self-contained ac-operated sensors

* Standard 2 m (6.5') cable models are listed.

9 m (30') cable: add suffix “W/30” (e.g., S183E W/30).

4-pin Micro-style QD models: add suffix “Q1” (e.g., S183EQ1). A model with a QD connector requires a mating cable. (See page 7.)

Use polarized models when shiny objects will be sensed.

Sensing Mode

Range

LED

Output

Model*

Opposed

20 m (66')

Infrared

950 nm

S183E

LO

S18AW3R

DO

S18RW3R

Retroreflective

2 m (79")

LO

S18AW3L

DO

S18RW3L

Polarized

Retroreflective

Visible Red

680 nm

LO

S18AW3LP

DO

S18RW3LP

Diffuse

100 mm (4")

Infrared

880 nm

LO

S18AW3D

DO

S18RW3D

300 mm (12")

LO

S18AW3DL

DO

S18RW3DL

Fixed-Field

25 mm (1") cutoff

LO

S18AW3FF25

DO

S18RW3FF25

50 mm (2") cutoff

LO

S18AW3FF50

DO

S18RW3FF50

100 mm (4") cutoff

LO

S18AW3FF100

DO

S18RW3FF100

P

Features

• Featuring EZ-BEAM

®

technology for reliable sensing without the need for

adjustments

• Completely epoxy-encapsulated to provide superior durability; designed to meet

rigorous IP69K standards for use in 1200 psi washdowns

• Innovative dual-indicator system takes the guesswork out of sensor performance

monitoring

• 20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum

load 300 mA

Models

WARNING . . .

Not To Be Used for Personnel Protection

Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.

These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety

applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.

Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for

personnel protection.

Advertising