Hookup and timing logic selection, Dimensions, q85 polarized retro sensors – Banner Q85 Series User Manual

Page 2

Advertising
background image

Banner Engineering Corp. 9714 10th Avenue No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications): (612) 544-3573

Hookup to the ac line and the external load is made at the five terminals

inside the wiring chamber (see drawing below). There is no polarity for

power supply hookup. Output is an SPDT electromechanical relay.

The output timing logic function (on sensor models with T9 model

number suffix) is selected at the timing logic programming switches,

according to the table (right). The output timing logic delays are set at

Timing logic

programming

switch detail:

With the light/dark operate switch (T9 models) set to light operate

(L.O.), the sensor's electromechanical output relay is energized when

the sensor sees the reflection of its own modulated light. In the dark

operate (D.O.) position, the output is energized when the sensor does

not see the reflection of its modulated light source.
Sensor sensitivity is set at the single-turn sensitivity adjustment po-

tentiometer.

Hookup and timing logic selection

Beam Pattern

Top view

Dimensions, Q85 polarized retro sensors

Shown with mounting bracket

(included)

Bottom view

Excess Gain Curve

WARNING

This photoelectric presence sensor does NOT include the self-checking redundant circuitry necessary to allow its use in personnel safety

applications. A sensor failure or malfunction can result in either an energized or a de-energized sensor output condition.
Never use this product as a sensing device for personnel protection. Its use as a safety device may create an unsafe condition which could lead to serious

injury or death. Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI

machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they

must NOT be used as sensing devices for personnel protection.

WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace, free of charge,

any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the

improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.

Logic function

Switch: SW1

SW2

SW3

ON and OFF delays (both)

0

0

0

ON delay (only)

0

0

1

OFF delay (only)

0

1

0

No delays

0

1

1

ON delayed one-shot

1

0

0

ON delayed limit timer

1

0

1

One-shot

1

1

0

Limit timer

1

1

1

the single-turn time adjustment potentiometer. When the timing function

involves more than one time (as in ON and OFF delay, ON-delayed

one-shot, and ON-delayed limit timer functions), the potentiometer sets

both times to the same value.