S2 series, Product specifications – Banner T30 Series User Manual

Page 5

Advertising
background image

S2 Series

Banner Engineering Corporation

page

5

Product Specifications

Supply Voltage and Current

Opposed Mode Emitter
Opposed Mode Receiver
Polarized Retro
Fixed-field

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

Sensing Output: PNP (current sourcing), light operated

Output Rating

150 mA maximum (each); the total load may not exceed 150 mA;
Off-state leakage current <1 microamp at 30V dc;
On-state saturation voltage <1V at 10 mA dc; <1.5V at 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short-circuit of outputs

Output Response Time

Opposed: 3 milliseconds "on" and 1.5 milliseconds "off"
Polarized Retro and Fixed-field: 3 milliseconds "on" and "off"

NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time

Indicators

Two LEDs: Green and Yellow

GREEN glowing steadily

= power to sensor is "on"

GREEN flashing

= output is overloaded

YELLOW glowing steadily = normally open output is conducting
YELLOW flashing

= excess gain marginal (1-1.5x) in light condition

Repeatability

Opposed: 375 microseconds
Polarized Retro and Fixed-field: 750 microseconds
Repeatability and response are independent of signal strength

Construction

Housings are VALOX

®

thermoplastic polyester; Lenses are Lexan

®

(opposed models) or acrylic (retro and fixed-

field models) S18 and S30 come with two jam nuts; T18, T30, Q25 and Q40 come with one jam nut

Environmental Rating

Leakproof design rated NEMA 6P; IEC IP67

Connections

4-pin euro-style quick-disconnect fitting; cables are ordered separately

Operating Temperature

-40° to +70°C (-40° to 158°F); Maximum relative humidity 90% at 50°C (non-condensing)

Vibration and
Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max.,
double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit
operating; 100G for non-operation)

10 to 30V dc (10% maximum ripple); Supply current (exclusive of load current):
25 mA
20 mA
30 mA
35 mA

Alarm Output: PNP (current sourcing), normally open
and conducts whenever the sensor's excess gain drops
to between 1X and 1.5X in the light condition

Advertising
This manual is related to the following products: