background image

BROWN

+10 - 30V dc

BLACK

BLACK wire
is not used

BLUE

(common)

WHITE

(sinking output)

1

2

3

4

5

6

7

8

dc+

dc com

I

N

P

U

T

S

P

r

o

g.

C

t

r

l.

Hookup shown is
typical for all inputs

Hookup Diagrams for dc SM912 Series Sensors

Hookup to dc Relay or
Solenoid

(using sinking output)

Hookup to dc Relay or
Solenoid

(using sourcing output)

The diagram below shows hookup of a dc VALU-
BEAM to a dc load using the sensor's sinking
output, which is rated at 250mA maximum.
The BLACK
wire is not
used.

The diagram below shows hookup of a dc VALU-
BEAM to a dc load using the sensor's sourcing
output, which is rated at 250mA maximum.
The WHITE
wire is not
used.

The diagram below shows hookup of a dc VALU-
BEAM to a logic gate. A logic zero (0 volts dc)
is applied to the gate input when the VALU-
BEAM output is energized. When de-energized,
a logic one is applied. The logic supply negative
must be common to the VALU-BEAM supply
negative.

Hookup to a Logic Gate

Hookup to MICRO-AMP Logic

(MPS-15 chassis)

Hookup to B Series Logic

(MRB chassis)

The current sinking output (white
wire) of the VALU-BEAM is shown
connected to the input (pin 5) of a B
Series module. It may be connected
to the auxiliary input (pin 3) if de-
sired. (See description of module
for function of aux. input). Any B
Series module may be used. Ban-
ner PLUG LOGIC modules may
also be used (contact the factory for
further information).

The current sinking output(s) of VALU-BEAM sen-
sors may be connected directly to the input of CL Series
MAXI-AMP modules. A MAXI-AMP which is pow-
ered by ac voltage offers a dc supply with the capacity
to power one VALU-
BEAM sensor (see
hookup diagram).
When emitter/receiver
pairs are used, the
emitter should be pow-
ered from a separate
power source.

Hookup to MAXI-AMP Logic Module

Emitter Hookup

(ac or dc power)

Hookup to Programmable Controller

(sinking output)

This diagram shows hookup of a dc VALU-BEAM to a programmable
controller requiring a current sink, using the sensor's sinking output. The
BLACK wire
is not used.

Hookup to Programmable Controller

(sourcing output)

This diagram shows hookup of a dc VALU-BEAM to a programmable
controller requiring a current source, using the sensor's sourcing output. The
WHITE wire is not used.

BLACK

BLACK
wire
is not used

(-) dc

BLUE

(common)

* Use pullup resistor to

logic supply

+5V to 30V dc
logic supply

*

BROWN

+10 -30V dc

WHITE (sinking)

output, 150mA max.

Hookup shown is
typical for all
inputs.

Hookup shown is
typical for all
inputs.

The current sinking (white) output of the VALU-BEAM is shown con-
nected to the primary input (pin 7) of a MICRO-AMP logic module. It may
be connected, instead, to the other inputs (see logic module descriptions in
the Banner product catalog). The following logic modules may be used:

BLUE

Micro-

Amp

Logic

BLACK wire
is not used

Relay

120
Vac

N
O

C

N
C

MODEL MPS-15

WHITE

BROWN

7
8
1
2

6
5
4
3

NO

NC

BLACK

MA4-2

One-shot

MA5

On/off delay

MA4G

4-input "AND"

MA4L

Latch

L1

L2

10 to 250V ac or V dc

SMA91E
SMA91EF
SMA91ESR

+
Brown


Blue

BLACK

(sourcing

output)

WHITE

BROWN

+10 - 30V dc

White wire
is not used

BLUE

(common)

1

2

3

4

5

6

7

8

dc+

dc com

I

N

P

U

T

S

P

r

o

g.

C

t

r

l.

Hookup shown is
typical for all inputs

BLACK wire
is not used

WHITE

BROWN

BLUE

+15V dc

120 Vac

B Series

Module

MRB

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

6

BLACK

BLACK wire
is not used

WHITE

BROWN

CL3RA

CL3RB

CL5RA

CL5RB

8

7

6

5

4

9

10

11

1

2

3

BLUE

BLACK

WHITE

BROWN

BLUE

BLACK

10 - 30V dc

LOAD

WHITE

BROWN

BLUE

BLACK

10 - 30V dc

LOAD

VALU-BEAM 912 Series Sensors

8

NOTE: each output has a maxi-
mum load capacity of 250mA.

For emitter hookup, see below.