Overview, Components and specifications, 7 specifications 2.7.1 general specifications – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 19

Advertising
background image

P/N 133487

17

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Overview

P/N 112852 rev. F

17

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

EZ-SCREEN

Instruction Manual

17

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com

Tel: 763.544.3164

Components and Specifications

2.7 Specifications
2.7.1 General Specifications

Short Circuit Protection

All inputs and outputs are protected from short circuits to +24V dc or dc common.

Electrical Safety Class

(IEC 61140: 1997)

III

Safety Rating

Type 4 per IEC 61496-1, -2; Category 4 PL e, per EN ISO 13849-1; SIL 3 per IEC 61508;

SIL CL 3 per IEC 62061

Resolution

and

Operating Range

Not including blanking

14 mm models: 0.1 m to 6 m (4" to 20')

30 mm models: 0.1 m to 18 m (4" to 60')

Range decreases with use of mirrors and/or lens shields:

Lens shields – approximately 10% less range per shield.

Glass-surface mirrors – approximately 8% less range per mirror.

See the specific mirror data sheet or the Banner Safety Catalog for further information.

Effective Aperture Angle

(EAA)

Meets Type 4 requirements per IEC 61496-2, Section 5.2.9

± 2.5° @ 3 m

Enclosure

Size: See Figure 2-2

Materials: Extruded aluminum housing with yellow polyester powder finish standard (optional black or

white or nickel-plated silver finish) and well-sealed, rugged die-cast zinc end caps, acrylic

lens cover, copolyester access cover. End caps on silver models are also nickel-plated.

ESD-safe models have static-dissipative acrylic lens cover.

Rating: IEC IP65

Operating Conditions

Temperature: 0° to +55° C (+32° to 131°F)

Max. Relative Humidity: 95% maximum relative humidity (non-condensing)

Shock and Vibration

EZ-SCREEN components have passed vibration and shock tests according to IEC 61496-1. This

includes vibration (10 cycles) of 10-55 Hz at 0.35 mm (0.014") single amplitude (0.70 mm peak-to-

peak) and shock of 10 g for 16 milliseconds (6,000 cycles).

Mounting Hardware

Emitter and receiver each are supplied with a pair of swivel end-mounting brackets. Models longer

than 900 mm also include a swivel center-mount bracket. Mounting brackets are 8-gauge cold-rolled

steel, black zinc finish.

Cables and Connections

See Section 2.3 for recommended QD cables. If other cables are used with the EZ-SCREEN, the user

must verify suitability of these cables for each application.

Certifications

IEC61496-1, -2: Type 4

ISO13849-1(EN954-1): Cat4

R

C

US

NIPF(7)

UL1998, UL61496

IEC 61496-1, -2: Type 4

EN ISO 13849-1: Cat 4 PL e

Advertising