7.5 Response Time for Cascaded Light Screens

Response time is an important factor in determining a light

screen’s separation (safety) distance. For cascaded (or

“daisy-chained”) EZ-SCREEN systems, that response time is

dependent on the number of light screens, the number of beams

in the light screens, and their positions in the cascade. It can be

calculated easily, in two ways:

Individually for each light screen in the cascade (separation

distance is calculated for each light screen in the cascade), or

Based on the worst-case time for the entire cascade (all light

screens in the cascade have the same separation distance).

Individual Response Time and Separation Distance

When calculating individual separation distance for each emitter/

receiver pair, the pair’s position in the cascade impacts its

response time, which then impacts its separation distance. This

method results in the closest possible separation distance for

each light screen.
Response time depends on how far “downstream” the light

screen is from the machine control. Each light screen position in

the cascade, starting from the first light screen in the cascade,

increases the light screen’s response time by 2 ms.
Figure 7-5 depicts a four-pair cascaded system. The 14 mm

resolution, 300 mm EZ-SCREEN emitter/receiver pairs each

begin with a response time of 15 ms. The pair in position #1

(connected directly to the machine control), maintains its

15 ms response time. Response time for the second pair in the

cascade circuit increases by 2 ms, to 17 ms; for the third pair by

4 ms, to 19 ms, and for the fourth pair by 6 ms, to

21 ms. The formula used for U.S. applications (other standards

may apply) to calculate separation distance for individual

placement of each emitter/receiver pair in the cascaded system

is:

Position #1: Ds = K (Ts + Tr) + Dpf

Position #2: Ds = K (Ts + Tr + 2 ms) + Dpf

Position #3: Ds = K (Ts + Tr + 4 ms) + Dpf

Position #4: Ds = K (Ts + Tr + 6 ms) + Dpf

Use the above formulas in place of the Ds formula in Section

3.1.1 to determine individual separation distance (Ds). This will

ensure each sensor pair is located at an adequate distance from

the hazard.

Figure 7-5. Calculating the individual response times of four, 14 mm

resolution, 300 mm cascaded Safety Light Screens

Overall Response Time and Separation Distance

The cascaded system’s Overall Response Time (Tr) is equal

to the response time of the individual sensor pair with the most

beams (i.e., the slowest individual response time), plus an adder

resulting from the number of systems in the cascade. Tr can be

found by the following formula:

Tr = Tr(max) + [(N-1) x 2 ms]

where:
Tr

(max)

is the response time of the slowest individual pair in the

cascade (i.e., the pair with the most beams; see Section 7.2).

N is the number of sensor pairs in the cascade.
Use this Tr value in the formula in Section 3.1.1 to determine

Overall Separation Distance (Ds). This will ensure that all sensor

pairs will be located at an adequate distance from the hazard, no

matter how the system is installed.

WARNING . . .

Proper Installation

The user must comply with all instructions within Section 3 for

proper installation. See Sections 7.2 and 3.1.1 for complete

information.

EZ-SCREEN

Position #3
15 + 2 + 2 = 19
19 ms Response

Emitters

Receivers

EZ-SCREEN

Position #4
15 + 2 + 2 + 2 = 21
21 ms Response

E-Stop (CSSI Input)

EZ-SCREEN

Position #2
15 + 2 = 17
17 ms Response

NOTE: Light screens of other lengths/

resolutions will have different

response times.

EZ-SCREEN

Position #1
15 ms Response

NOTE: EZ-SCREEN Cascade

Overall System Response

15 + [(4 – 1) × 2 ms]

15 + 6

21 ms response

Machine

Control

CSSI Response Time = 40 ms + [(4 – 1) × 2 ms] = 46 ms