EZ-SCREEN

Instruction Manual

System Operation

4.3 Reset Procedures

Resetting the System

System resets are performed using an external reset switch.

This switch must be located outside the guarded area, and must

not be within reach from within the guarded area (see Section

3.1.3). Its location should provide a clear view of the entire

safeguarded area. If any hazardous areas are not in view from

the switch location, additional means of safeguarding must be

provided. The switch should be protected from accidental or

unintended actuation (e.g., through the use of rings or guards).
If supervisory control of the reset switch is required, a key

switch may be used, with the key kept in the possession of a

Designated or Qualified Person. Using a key switch will also

provide some level of personal control, since the key may be

removed from the switch. This will hinder a reset while the key

is under the control of an individual, but must not be relied upon

solely to guard against accidental or unauthorized reset. Spare

keys in the possession of others or additional personnel entering

the safeguarded area unnoticed may create a hazardous

situation.

Receiver Resets

The EZ-SCREEN receiver has a Reset input, pin 8 (Violet wire),

that allows the System to be manually reset.
The EZ-SCREEN requires a manual reset to clear a Latch

condition and resume operation following a stop command.

Internal Lockout conditions also require a manual reset to return

the System to RUN mode after the failure has been corrected

and the input correctly cycled.
Receiver manual resets are required in the following

situations:

Trip Output operation – only after a System Lockout (see

Section 5 for causes).

Latch Output operation – at power-up, after each Latch

condition occurs, and after a System Lockout.

Reset Routine

To reset the receiver, close the reset switch for 1/4 to 2 seconds,

then open the switch. (If reset switch model MGA-KS0-1, listed

in Section 2, is used, turn the key 1/4 turn clockwise to close;

turn counterclockwise, back to its original position, to open.)
NOTE: Closing the reset switch too long will cause the System

to ignore the reset request; the switch must be closed

from 1/4 second to 2 seconds, but no longer.

Emitter Resets

In the rare occurrence that an emitter requires a reset, power

the sensor down, then power it up. Emitter resets are needed

only if a Lockout occurs.

Accessing the Configuration Panel

To open the access cover for DIP switch configuration:
1. Remove the security plate using the special tool supplied.
2. Using a small flat blade screwdriver or the security plate tool,

push the plastic tab on the access cover inwards at a 45°

angle.

3. Pivot the screwdriver against the bevel until the access cover

pops open.

4. To close the access cover, simply push cover into place (it will

“snap” into place). The access cover has been designed to be

removable, so if it should come off, simply snap it back onto

the hinge and close it.

5. If required, replace the security plate with tamper-resistant

screws provided, using the same supplied tool.

It is important to snap-close the cover to maintain the sensors’

IP 65 environmental rating. In the event an access cover is lost

or damaged, it can be re-ordered (see Section 2.5, Replacement

Parts). It is recommended for installations subject to shock and

vibration, that the security plate be reinstalled.

Figure 4-2. Accessing the configuration switches

1. Remove Security Plate

2. Open Access

Cover