Wiring, Overview – Banner MINI-BEAM Expert Series User Manual

Page 2

Advertising
background image

Glass Fiber Optic Models

Sensing Mode

Model *

Range or Focus

Supply Voltage

Output Type

Glass Fiber Optic, 880 nm infrared

SME312F

Range varies by sensing mode and
fiber optics used

10 to 30V dc

Bipolar NPN/PNP

Glass Fiber Optic, 650 nm visible red

SME312FV

Glass Fiber Optic, 525 nm visible green

SME312FVG

Glass Fiber Optic, 475 nm visible blue

SME312FVB

Glass Fiber Optic, 450-650 nm visible white

SME312FVW

Plastic Fiber Optic Models

Sensing Mode

Model *

Range or Focus

Supply Voltage

Output Type

Plastic Fiber Optic, 650 nm visible red

SME312FP

Range varies by sensing mode and
fiber optics used

10 to 30V dc

Bipolar NPN/PNP

Plastic Fiber Optic, 525 nm visible green

SME312FPG

Plastic Fiber Optic, 475 nm visible blue

SME312FPB

Plastic Fiber Optic, 450-650 nm visible white

SME312FPW

* Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix “W/30” to the model number (e.g., SME312LV W/30.) To order the 5-pin
Euro-style QD models, add suffix “QD” (e.g., SME312LVQD). Models with a QD connector require a mating cable.

Wiring

Cabled Models

QD Models

bn

Remote
Teach

bu
wh
bk
gy

+

10-30V dc

Load
Load

bn

Remote
Teach

bu
wh
bk
gy

+

10-30V dc

Load
Load

Overview

Yellow output
indicator LED

Bi-color green/red
indicator LED

MINI-BEAM® Expert™ is a complete family of sensors, all housed in the popular, robust and compact rec-
tangular housing. Their large push button and easy-to-see indicators provide easy configuration, alignment,
and monitoring during use.

Status Indicators

Normal sensor operation is called RUN mode. Sensor configuration (setting the sensitivity threshold and selecting output ON and OFF conditions) is performed in TEACH
mode. The two LED indicators (bi-color green/red and yellow) have distinct roles in the two operation modes. If contrast is marginal, the bi-color indicator will flash green to
indicate instability. If this occurs, reconfigure or realign the sensor, or clean the sensor or fiber lenses.
The Signal Strength indicator is Banner’s exclusive AID™ (Alignment Indicating Device). Its pulse rate increases as the received light signal strength increases (during
programming). This feature simplifies accurate alignment during TEACH mode, and gives a relative indication of sensing contrast between the light and dark conditions.

LED

RUN Mode

TEACH Mode

Solid green

Power is on

Flashing green

Sensed light level is approaching sensing threshold*

MINI-BEAM Expert Series Installation Guide

2

www.bannerengineering.com - tel: 763-544-3164

P/N 068812 Rev. B

Advertising