Banner U-GAGE Q45U Series—Analog User Manual

Q45uml master window limit programming card, Features

Advertising
background image

Q45UML Master Window Limit Programming Card

For use with Q45U Ultrasonic Proximity Mode Sensors

Printed in USA

P/N 50372

• Transfer the programmed sensing window limit settings from any Q45U sensor to the

master window limit programming card

• Card stores window limit settings in non-volatile memory

• Transfer window limit settings stored on a card back to the Q45U sensor at any time

• Transfer window limit settings stored on one card to any Q45U which has the same

sensing range as the sensor used to store the limit settings (i. e. - either long range
or short range)

Features

Description
The Q45UML plugs into any Q45U ultrasonic proximity mode sensor in place of the
sensor’s output card. It can download the sensing window limit settings from the
sensor it is plugged into. Those sensing limit settings are stored on the card in non-
volatile memory, until new sensing limit settings are downloaded to it.

The sensor limit settings residing on the Q45UML card may be transferred to any
Q45U sensor, as long as that sensor has the same range (long or short range) as the
sensor used to store the limit settings on the Q45UML.

Storing Window Limit Settings on the Q45UML Card
Use the following procedure to copy sensing window limit settings from a Q45U
sensor to the Q45UML master window limit programming card:

1)

Remove power from the Q45U sensor.

2)

Remove the output card from the Q45U sensor (Figure 1). Use a small
screwdriver, or similar tool, to dislodge the output card from its connector.
Then, slide the card out of the sensor.

3)

Turn switch #1 on the Q45UML card to “off” (see Figure 2). Note that only
switch #1 is used. Switches #2, 3, and 4 have no function.

4)

Slide the Q45UML card into the sensor in place of the sensor output card
(Figure 3). Push it firmly into place.

5)

Apply power to the sensor. The window limits are copied to the Q45UML card
when power is applied to the sensor. The center three segments of the 5-
segment LED indicator on the Q45UML will flash simultaneously to verify that the
limit settings have been copied to the card.

6)

Remove power from the Q45U sensor.

7)

Remove the Q45UML card in the same manner used to remove the output card in
step 2 (Figure 1).

8)

Turn switch #1 on the Q45UML to “on” (Figure 2) to lock the window limit
settings into memory.

9)

Slide the output card back into the Q45U sensor, and push firmly into place.

Figure 1.

Remove the output card
using a small screwdriver
to dislodge it from its
connector.

Figure 2.

Switch settings