Banner U-GAGE M25U Ultrasonic Sensors User Manual

U-gage, M25u series sensor, Features

Advertising
background image

U-GAGE

®

M25U Series Sensor

Ultrasonic Opposed Mode Sensor Pairs

Printed in USA

04/09

P/N 137794 rev. D

WARNING . . .

Not To Be Used for Personnel Protection

Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.

These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A
sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner
Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.

Features

Smooth, hygienic design for easy cleaning in food processing and other washdown

applications; rated IP69K, IEC IP67 (NEMA 6)
Rugged stainless steel for use in demanding environments

Dual range/dual speed opposed mode ultrasonic sensors; ideal for sensing clear

objects or materials
Highly immune to ambient sonic and electrical noise

Optional IP68 rated washdown cordset

10 to 30V dc operating voltage

Models

* M25U receivers may be wired for either of two speeds: Normal or High (see hookup diagrams, page 3). The Normal Speed mode offers a sensing range of 500 mm (19.7"). The

Normal Speed mode maximizes sensing energy, as is required in demanding environments. The High Speed mode offers a sensing range of 250 mm (9.8"). The High Speed
mode maximizes sensing response, as is needed in high-speed counting applications.

Model

Range*

Supply Voltage

Output

Response Time

M25UEQ8

Normal Speed: 500 mm (19.7")

High Speed: 250 mm (9.8")

140KHz

10 to 30V dc

M25URBQ8

Bipolar (1 NPN & 1 PNP)

Normal Speed: 4.0 milliseconds

High Speed: 3.0 milliseconds

ULTRASONIC

Advertising