5.1.1 Receiver Error Codes (continued)

Diagnostic

Display

Error Description

Cause of Error and Appropriate Action

EDM 2 Error
EDM 2 configuration not valid (wiring or
switch).

• Verify that the EDM wiring is correct and that the external devices meet the

requirements described in Section 3.5.3.

If the error continues, remove power to the guarded machine, disconnect the

OSSD loads, disconnect the EDM input signals, configure EDM for no monitoring
(per Section 3.5.3) and conduct the initial checkout procedure (Section 3.4).

If the error clears, the problem is in the external device contacts or wiring, or is

a response-time problem of the external devices. Verify that the EDM wiring is
correct
and that the external devices meet the requirements described in Section
3.5.3.

If the error continues, check for noise on the EDM inputs (see Section 5.3).

Fixed Blanking Error
This error occurs when beam(s) that
have been blanked (programmed to
ignore a fixed object) become clear
when the object is removed or moved.

• Reposition the object and perform a key reset (or cycle power).
• Re-program (teach) the fixed blanked object(s), see Sections 3.4.3 and 7.10.

Programming Timeout Error
This error occurs when the Fixed
Blanking programming mode (teach)
exceeds the ten-minute limit.

• Re-program (teach) the fixed blanked object(s), see Sections 3.4.3 and 7.10.

Cascade Configuration Error
This error occurs when the configuration
sequence is incorrectly followed,
receiver(s) 2, 3 or 4 are configured,
or receiver 1 is moved to a different
position in the cascade.
If this code appears for a non-
cascaded application, check EDM
wiring.

• The CSSI input channel(s) are shorted together or to another source of power or

ground.

• Configure ONLY the first receiver in the cascade (connected to the machine

interface). All other receivers must be set for 2-channel EDM and trip output (T),
see Section 7.7.

• Re-configure the first receiver to adapt System to changes or replacement of other

receivers, see Section 7.7.

• See Section 7.10 for Remote Fixed Blanking procedures.
NOTE: In a cascaded System, all receivers are connected together, and all

emitters are connected together.

Excessive Noise Error –
Reset Interface

This error can occur due to excessive
levels of electrical noise.

• Perform a reset per Section 4.3.
If the error clears, perform the daily checkout procedure (per Section 6.3; Daily

Checkout Card) and if OK, resume operation. If the System fails the Daily
Checkout procedure, replace the receiver.

If the error continues, check the ground connection (pin 7).
If the sensor has a good earth ground connection to pin 7, perform the Initial

Checkout procedure (Section 3.4).

If the error clears, check for sources of electrical noise (see Section 5.3).
If the error continues, replace the receiver.

Excessive Noise Error –
EDM Interface

This error can occur due to excessive
levels of electrical noise.

Excessive Noise Error –
Cascade Input

This error can occur due to excessive
levels of electrical noise.

Flashing

Cascade Input Simultaneity
Operation of channels A and B
mismatch > 3 seconds.

• Check operation of Channel A and Channel B of cascade input.
• Cycle power or cycle the input. See Sections 7.8 and 7.9.

Axx”/“bxx”,

where “xx” are

alpha-numeric

characters

Advanced Diagnostics for the purpose
of factory troubleshooting and repair;
not intended for field troubleshooting.

If advanced diagnostic codes are inadvertently displayed, toggle the Invert Display
DIP switch (to the opposite state and back, within 1 second) to return to the standard
error code display.