D11 series, Quick disconnect (qd) cables, Hookup diagrams – Banner D11 Series User Manual
Page 3: Warning
D11 Series
Banner Engineering Corporation
page
3
Quick Disconnect (QD) Cables
28 mm max.
(1.1 in)
ø10 mm max.
(0.4 in)
The following is the selection of cables available for D11 QD models
DImensions
Style
Model
Length
For use with
4-pin
Pico Style
straight
PKG4-2
2 m (6.5 ft)
All D11 sensors with
quick-disconnect fitting
Black Wire
Blue Wire
Brown Wire
White Wire
Pinout
20 mm
(0.8 in)
25 mm max.
(1.0 in)
ø12 mm max.
(0.5 in)
4-pin
Pico Style
right-angle
PKW4-2
2 m (6.5 ft)
Sensors with NPN (Sinking) Outputs
Sensors with PNP (Sourcing) Outputs
Standard Hookup
Standard Hookup
bu
bn
-
+
bk
wh
Load
Load
Load
Load
5V dc
bn
bu
-
+
bk
wh
Load
Load
5V dc
Hookup Diagrams
Note: Connections are the same for either an integral cable or QD cable.
WARNING
These photoelectric presence sensors do NOT include the self-checking redundant circuitry
necessary to allow their use in personnel safety applications. A sensor failure or malfunction can result in either
an energized or a de-energized sensor output condition.
Never use these products as sensing devices for personnel protection. Their use as a safety device may create
an unsafe condition which could lead to serious injury or death.
Only MINI-SCREEN
™
, MULTI-SCREEN
™
, MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so
designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other
Banner sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for
personnel protection.
!