www.bannerengineering.com • Tel: 763.544.3164

Supply Voltage and Power

10 to 30V dc (10% maximum ripple) at less than 1 watt each for emitter and receiver (exclusive of load)

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Sensing Range

Normal (see hookups)

Reduced

Short-Range Models

100 to 200 mm (4" to 8")

75 to 150 mm (3" to 6")

Standard-Range Models

300 mm to 2 m (1' to 6.5')

150 mm to 600 mm (6" to 24")

Output Configuration

Bipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor

Output Rating

125 mA maximum each output

Off-state leakage current: less than 5 microamp

Output saturation voltage (PNP output): < 1 volt at 10 mA and < 1.5 volts at 100 mA

Output saturation voltage (NPN output): < 0.5 volts at 10 mA and < 0.6 volts at 100 mA

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short circuit of outputs

Output Response Time

LX3: 0.8 ms ON-time; 6 ms OFF-time (5 ms OFF-delay) LX15: 4.0 ms ON-time; 9 ms OFF-time (5 ms OFF-delay)

LX6: 1.6 ms ON-time; 7 ms OFF-time (5 ms OFF-delay) LX18: 4.8 ms ON-time; 10 ms OFF-time (5 ms OFF-delay)

LX9: 2.4 ms ON-time; 7.5 ms OFF-time (5 ms OFF-delay) LX21: 5.6 ms ON-time; 11 ms OFF-time (5 ms OFF-delay)

LX12: 3.2 ms ON-time; 8.5 ms OFF-time (5 ms OFF-delay) LX24: 6.4 ms ON-time; 11.5 ms OFF-time (5 ms OFF-delay)

Minimum Object Detection

Size (M.O.D.S.)

Smallest diameter rod that can be detected in sensing range: Short-Range: 5.6 mm (0.22")

Standard-Range: 9.5 mm (0.38")

Indicators

Emitter:

LED1 (green)

LED2 (red)

ON: Power ON, good sensor

ON: Reduced range

OFF: Reduced Range

OFF: Normal range

Flashing: Emitter hardware failure

Receiver: LED1 (yellow)

LED2 (bicolor green/red)

ON: Output conducting

Green: Normal range

OFF: Output not conducting

Red: Reduced range

Flashing Red: Receiver hardware failure

Construction

Aluminum housing, die cast zinc with black e-coat painted endcaps, acrylic lens window

Environmental Rating

Meets IEC IP65

Connections

2 meter (6.5') 5-conductor (with drain) pvc-jacketed attached cable or 5-pin Euro-style 150 mm (6") QD pigtail,

depending on model

Operating Conditions

Temperature: -20° to +70° C (-4° to +158° F)
Max. rel. humidity: 90% at 50° C (non-condensing)

Application Notes

i) The best sensing resolution occurs within the center 80% of the sensing range (see Figure 1).

ii) Low-profile packages can be reliably detected.

iii) Outputs are active while the light screen is interrupted.

iv) For reliable detection, successive parts must be spaced up to the total of ON-time plus OFF-time apart.

(ie: 12 milliseconds for the LX12)

Certifications

Specifications

Hookups

*It is recommended that the shield wire be connected to earth ground or DC common.

bk
gy

bn
bu
wh

10 - 30V dc

shield*

Select

Reduced

0 - 2V dc

Load

Load

Normal

5-30V dc

bk
gy

bn
bu
wh

10 - 30V dc

shield*

Select

Reduced

0 - 2V dc

Normal

5-30V dc

No Connection

No Connection

Receiver

Emitter

Load

Load

bk
gy

bn
bu
wh

10 - 30V dc

shield*

Select

Reduced

0 - 2V dc

Normal

5-30V dc

bk
gy

bn
bu
wh

10 - 30V dc

shield*

Select

Reduced

0 - 2V dc

Normal

5-30V dc

Receiver

Emitter

No Connection