Specifications – Banner SureCross DX81 FlexPower Supply Module User Manual

Page 2

Advertising
background image

3. Remove the discharged battery by pressing the battery towards the negative terminal to compress the spring. Pry up

on the battery’s positive end to remove from the battery holder.

4. Replace with a new battery. Only use a 3.6 V lithium battery from Xeno, model number XL-205F.
5. Verify the battery’s positive and negative terminals align to the positive and negative terminals of the battery holder

mounted within the case. Caution: There is a risk of explosion if the battery is replaced incorrectly.

6. After replacing the battery, allow up to 60 seconds for the device to power up.
7. Properly dispose of your used battery according to local regulations by taking it to a hazardous waste collection site, an

e-waste disposal center, or any other facility qualified to accept lithium batteries.

As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn

or expose them to high temperatures. Do not recharge, crush, disassemble, or expose

the contents to water.

The battery may be replaced in explosive gas atmospheres.

Replacement battery model number: BWA-BATT-001. For pricing and availability,

contact Banner Engineering.

Specifications

Estimated Battery Life

19,000 mA·hours

Housing

Polycarbonate housing and rotary dial cover; polyester

labels; EDPM rubber cover gasket; nitrile rubber, non-

sulphur cured button covers
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (SS M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)

Wiring Access

One 1/2-inch NPT with 5-pin Euro-style 150 mm

pigtail QD

DX8x...C (External Wiring Terminal Models)

CSA: Class I, Division 2, Groups A, B, C, D

(Ex/A Ex nA II T4); Certificate: 1921239

LCIE/ATEX: Zone 2 (II 3G / Ex nA IIC);

Certificate: LCIE 10 ATEX 1012 X

Environmental Rating

Rating: IEC IP67; NEMA 6; (See UL section below for

any applicable UL specifications)

Operating Conditions

Operating Temperature: −40 to 85 °C
Operating Humidity: 95% max. relative (non-

condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz

(EN61000-6-2)

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

Operating the devices at the maximum operating conditions

for extended periods can shorten the life of the device.

SureCross DX81 FlexPower Supply Module

2

www.bannerengineering.com - tel: 763-544-3164

P/N 131596 Rev. E

Advertising