Banner U-GAGE Q45U Series—Analog User Manual

45lma analog output card, Features, Installing the 45lma card

Advertising
background image

45LMA Analog Output Card

For use with Analog Q45U Ultrasonic Proximity Mode Sensors

Printed in USA

05/01

P/N 57539

Limits

N

1 2 3 4 5

5-Segment Target

Position Indicator

(N = Near)

Slots for Inner
Cover Removal

Resp.
Speed

+

Response
Adjustment

Figure 1. Analog Q45U (45LMA card) features

Features

• Analog Output Card plugs into any Q45U ultrasonic proximity mode sensor in place

of the existing output card.

• Selectable 0 to 10V dc voltage-sourcing or 4 to 20 mA current-sourcing analog

outputs

• Selectable output slope: positive or negative as target distance increases

Installing the 45LMA Card

Use the following procedure to install the 45LMA Analog Output Card:

1) Remove power from the Q45U sensor.

2) Remove the output card from the Q45U sensor (Figure 1). Use a small

screwdriver, or similar tool, to dislodge the output card from its connector.
Then, slide the card out of the sensor.

3) Slide the 45LMA card into the sensor in place of the sensor output card

(Figure 3); push it firmly into place.

4) Configure DIP switches as necessary. See programming instructions and table for

information.

5) Apply power to the sensor.