Q60laf series laser adjustable-field sensors, Specifications – Banner Q60 Background Suppression Series User Manual

Page 9

Advertising
background image

P/N 114348

9

Q60LAF Series Laser Adjustable-Field Sensors

Banner Engineering Corp.

Minneapolis MN, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Specifications

Supply Voltage and
Current

Q60BB6LAF models: 10 to 30V dc (10% maximum ripple) at less than 35 mA exclusive of load
Q60VR3LAF Universal models: 12 to 250V dc or 24 to 250V ac, 50/60 Hz

Input power 1.5 W maximum

Supply Protection

Protected against reverse polarity and transient voltages

(Q60VR3 models’ dc hookup is without regard to polarity)

Output Configuration

Q60BB6LAF models: Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector

transistor

Q60VR3LAF cabled model: E/M Relay (SPDT), normally closed and normally open contacts
Q60VR3LAFQ1 (QD) model: E/M Relay (SPST), normally open contact

Output Rating

Q60BB6LAF models

Q60BB6LAF models

150 mA maximum each output @ 25° C
Off-state leakage current: < 5µA @ 30V dc
Output sat u ra tion NPN: < 200 mV @ 10 mA and < 1V @150mA
Output sat u ra tion PNP: < 1V at 10 mA; < 1.5V at 150 mA
Q60VR3LAF Universal models

Q60VR3LAF Universal models
Min. voltage and current:
5V dc, 10 mA
Mechanical life of relay: 50,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations
Max. switching power (resistive load): Cabled models: 1250VA, 150 W

QD models: 750VA, 90W

Max. switching voltage (resistive load): Cabled models: 250V ac, 125V dc

QD models: 250V ac, 125V dc

Max. switching current (resistive load):

Cabled models: 5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc
QD models: 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc

Output Protection
Circuitry

Q60BB6LAF models: Protected against continuous overload or short circuit of outputs
All models: Protected against false pulse on power-up

NOTE: 1 second max. delay at power up (outputs do not conduct during this time).

Output Response Time

Q60BB6LAF models: 2 milliseconds ON and OFF
Q60VR3LAF Universal models: 15 milliseconds ON and OFF

Repeatability

500 microseconds

Sensing Hysteresis

See Figure 4.

Indicators (see Figure 1)

NOTE: Outputs are

active during
on/off timing
selection mode.

ON-Delay

ON Green: RUN mode, ON-delay active
Flashing Green: ON-Delay Selection mode

OFF-Delay

ON Green: RUN mode, OFF-delay active
Flashing Green: OFF-Delay Selection mode

5-Segment Light Bar*

ON/OFF-Delay Selection: Indicates relative delay time
RUN Mode:

Output

ON Yellow: Outputs are conducting

ON Green: ON/OFF-Delay Selection

Dark Operate

ON Green: Dark Operate selected

Lockout

ON Green: Buttons locked out

Light Operate

ON Green: Light Operate selected

Signal

ON Green: Sensor receiving signal
Flashing Green: Marginal signal (1.0 to 2.25 excess gain)

Laser Characteristics

Spot Size: approximately 4 x 2 mm throughout range (collimated beam)

Angle of Divergence: 5 milliradians

NOTE: Contact factory for custom laser spot size.