Specifications

Supply Voltage and Current

10 to 30V dc (10% max. ripple); supply current (exclusive of load

current):
Emitters, Non-Polarized, Retro, Diffuse: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Indicators

Two LEDs (Green and Yellow)
Green ON solid: power to sensor is ON
Green flashing: output is overloaded
Amber ON solid: N.O. output is conducting
Amber flashing: excess gain marginal (1 to 1.5x) in light condition

Construction

PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens

Environmental Rating

Leakproof design rated NEMA 6P, DIN 40050 (IP69K)

Connections

2 m (6.5 ft) or 9 m (30 ft) attached cable or 4-pin Euro-style quick-

disconnect fitting

Operating Conditions

Temperature: –40 to +70 °C (–40 to +158 °F)
Maximum relative humidity: 90% at 50 °C (non-condensing)

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration;

frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration

10G). Method 213B conditions H&I (Shock: 75G with unit operating;

100G for non-operation)

Output Configuration

SPDT solid-state dc switch; NPN (current sinking) or PNP (current

sourcing), depending on model
Light Operate: N.O. output conducts when sensor sees its own (or the

emitter’s) modulated light
Dark Operate: N.C. output conducts when the sensor sees dark; the

N.C. (normally closed) output may be wired as a normally open

marginal signal alarm output, depending upon hookup to power supply

Output Rating

150 mA maximum (each) in standard hookup. When wired for alarm

output, the total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V @ 10 mA dc; < 1.5V @ 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or

short circuit of outputs

Output Response Time

Opposed mode: 3 ms ON, 1.5 ms OFF
Retro, Fixed-Field and Diffuse: 3 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do not conduct during this

time.

Repeatability

Opposed mode: 375 μs
Retro, Fixed-Field and Diffuse: 750 μs
Repeatability and response are independent of signal strength.

Certifications

Performance Curves

Opposed Mode

Excess Gain

Beam Pattern

1

10

100

1 m

(3.3')

10 m

(33')

100 m

(330')

0.1 m

(0.33')

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

S18 Series

Opposed Mode

25 m

(82')

20 m

(66'

15 m

(49')

10 m

(32')

5 m

(16')

0

0

500 mm

1000 mm

1500 mm

500 mm

1000 mm

1500 mm

0

20"

40"

60"

20"

40"

60"

DISTANCE

S18 Series

Opposed Mode

)

S18 Sensors (DC-Voltage Series)

4

www.bannerengineering.com - tel: 763-544-3164

P/N 121522 Rev. B