Sl0 series slot sensor, Sl0 series slot sensor specifications, Sl0 series slot sensor hookups – Banner SL30 Series Slot Sensors User Manual

Page 3: Cabled models, Quick-disconnect models

Advertising
background image

SL0 Series Slot Sensor

page

3

Banner Engineering Corp. • Minneapolis, U.S.A.
Website: http://www.baneng.com • Tel: 888.373.6767

Figure 3. SL0 Series Slot Sensor dimensions

M12 x 1

Signal LED

(Yellow)

Power LED

(Green)

20.2 mm (0.80")

18.8 mm

(0.74")

6.0 mm
(0.24")

2x ø5.6 mm
(0.22")

6.0 mm

(0.24")

10.9 mm
(0.43")

10.0 mm

(0.39)

30.2 mm

(1.19")

45.0 mm

(1.77")

72.0 mm

(2.84")

40.0 mm

(1.58")

52.0 mm

(2.05")

SL0 Series Slot Sensor Specifications

Slot Opening

30 mm (1.2") wide x 45 mm (1.8") deep overall; beam set in 10 mm (0.4") from outer edge

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

Bipolar: NPN (current sinking) and PNP (current sourcing)

Output Rating

150mA, each output

Output Protection Circuitry

Protected against false pulse on power-up and short-circuit of outputs

Output Response Time

1 millisecond or 300 microseconds, depending on model

Repeatability

250 microseconds or 75 microseconds, depending on model

Adjustments

None

Indicators

Green:

Power ON/OFF indicator

Yellow: Signal Condition indicator

Construction

Housing:

ABS/polycarbonate

Lenses:

Acrylic

Environmental Rating

IP67, NEMA 6

Connections

2 m (6.5') or 9 m (30') 5-conductor PVC-jacketed attached cable or 5-pin Euro-style quick-disconnect
(QD) connector. QD cables are ordered separately; see page 4.

Operating Conditions

Operating Temperature:

-40° to +70°C (-40° to +158°F)

Maximum relative humidity:

90% @ 50°C (non-condensing)

Supply Voltage and Current

10 to 30V dc, 30 mA

SL0 Series Slot Sensor Hookups

bn
bu
wh
bk
gy

+

10 - 30V dc

Load
Load

(See right*)

Cabled models

bn
bu
wh
bk
gy

+

10 - 30V dc

Load
Load

(See left*)

Quick-Disconnect models

*For Dark Operate, connect gray wire

to + (brown).