Osblvagc, Sensor head, Osblvagc sensor head specifications – Banner OMNI-BEAM Series User Manual

Page 5

Advertising
background image

Sensing mode: Polarized retroreflective; use with Banner BRT-.6,
BRT-1, BRT-1.5, or BRT-3 corner cube retroreflector

Sensing beam: Visible red, 650 nm

Response time: 4 milliseconds on and off
Repeatability: 0.2 milliseconds

Construction: OMNI-BEAM sensor heads are molded from rugged
VALOX

®

thermoplastic polyester for outstanding electrical and me-

OSBLVAGC Sensor Head Specifications

OMNI-BEAM's
sensor block and
power block bolt and
plug together quickly
and easily.

An optional timing
logic module may be
added at any time.

!

WARNING

OMNI-BEAM photoelectric

presence sensors do NOT include the self-checking
redundant circuitry necessary to allow their use in
personnel safety applications. A sensor failure or
malfunction can result in either an energized or a
de-energized sensor output condition.

Never use these products as sensing devices for personnel protection.
Their use as safety devices may create an unsafe condition which could
lead to serious injury or death.

Only MACHINE-GUARD and PERIMETER-GUARD Systems, and
other systems so designated, are designed to meet OSHA and ANSI
machine safety standards for point-of-operation guarding devices. No
other Banner sensors or controls are designed to meet these standards,
and they must NOT be used as sensing devices for personnel protection.

OSBLVAGC Dimensions (with dc Power Block)

OSBLVAGC Dimensions (with ac Power Block)

OSBLVAGC

Sensor Head

5

VALOX

®

and LEXAN

®

are registered trademarks of General Electric Company.

Logic Modules

Power Blocks

Logic Modules and Power Blocks for the OSBLVAGC Sensor Head

chanical performance in demanding applications. The top view
window is LEXAN

®

polycarbonate. Lenses are acrylic. Hardware is

stainless steel. When assembled, all parts are fully gasketed. Rated
NEMA 1, 2, 3, 3S, 4, 12, and 13 when assembled.

Operating Temperature Range: -40 to +70

°

C (-40 to +158

°

F)

Delay upon power-up: 200 milliseconds maximum (power block
outputs are non-conducting during this time

Timing logic may be added to the OSBLVAGC at any time. Timing
logic modules simply slide into the sensor block module. There are
three models:

OLM5

ON-delay or OFF-delay or ON/OFF delay

OLM8

One-shot or delayed one-shot, 15 sec. max.

OLM8M1

One-shot or delayed one-shot, 1 sec. max.

The power block determines the sensor operating voltage and also the
sensor output switch configuration. Models are available with a built-
in 6-foot long cable, or with either of two styles of quick-disconnect
("QD") plug-in cable fittings. See page 6 for detailed QD cable
information. See also data sheet 32888 for further information about
OMNI-BEAM power blocks.

Model

Operating Voltage, cabling

OPBT2

10 to 30V dc Bi-Modal, prewired cable

OPBT2QD

10 to 30V dc Bi-Modal, integral minifast™ QD

OPBT2QDH 10 to 30V dc Bi-Modal, integral eurofast™ QD*

OPBA2

105 to 130V ac, prewired cable

OPBA2QD

105 to 130V ac, integral minifast™ QD

OPBB2

210 to 250V ac, prewired cable

OPBB2QD

210 to 250V ac, integral minifast™ QD

*Contact factory for availability of eurofast™ models.