Sensing Beam

Cutoff Point Tolerance

±10% of nominal cutoff distance

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

SPDT (complementary) solid-state dc switch; choose NPN (current sinking) or PNP (current sourcing) models.

Light operate: N.O. output conducts when the sensor sees its own modulated light
Dark operate: N.C. output conducts when the sensor sees dark

Output Rating

100 mA maximum (each output)
OFF-state leakage current: < 5 microamps at 30V dc
ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 100 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or short-circuit of outputs
Overload trip point

150mA, typical, at 20ºC

Output Response Time

1 millisecond on and off
NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time

Indicators

Two LEDs: Green and Yellow

GREEN glowing steadily

= power to sensor is ON

GREEN flashing

= output is overloaded

YELLOW glowing steadily = light is sensed; normally open output ON
YELLOW flashing

= marginal excess gain (1-1.5x) in light condition

Repeatability of Response

250 microseconds

Certifications

Construction

Housings are die-cast zinc alloy with black acrylic polyurethane finish; lenses are acrylic

Environmental Rating

IP67; NEMA 6

Connections

2 m (6.5') or 9 m (30') attached cable, or 4-pin Euro-style quick-disconnect fitting; cables for QD models
are purchased separately

Operating Conditions

Temperature: -20º to +55ºC (-4º to 131ºF)
Maximum relative humidity: 90% at 50ºC (non-condensing)

Sensing Hysteresis

Less than 5% of cutoff distance - 2000 mm models
Less than 4% of cutoff distance - 1500 mm models
Less than 3% of cutoff distance - 1000 mm models
Less than 2% of cutoff distance - 750 mm models
Less than 1% of cutoff distance - 500 mm models

Infrared, 880 nm

Supply Voltage and Current

10 to 30V dc (10% maximum ripple) at less than 40 milliamps

QMT42 Series Fixed-Field Mode Specification

Interpretation of Cutoff Point Deviation Curve
The percentage of deviation indicates a change in the cutoff
point for either 18% gray or 6% black targets, relative to the
cutoff point for a 90% reflective white test card.

As an example, the cutoff point decreases 10% for a 6%
reflectance black target when the cutoff point is 2000
millimeters (79") using a 90% reflectance white test card. In
other words, the cutoff point for the black target is 1800
millimeters (71").

0

-8

-10

-6

-4

-2

0

+2

+4

+6

+8

+10

500 mm

(20 in)

750 mm

(30 in)

1000 mm

(39 in)

1500 mm

(59 in)

Cutoff Point Variation Relative to 90% Reflectance White Test Card

Percent

Deviation

2000 mm

(79 in)

18% Gray Color Sensitivity

6 % Black Color Sensitivity

Cutoff Point Deviation