Status Indicators/Troubleshooting

MODE

Status Indicator #1

Status Indicator #2

Figure 7. Status indicators

Indicator Condition

Description

#1

Steady Yellow

Output is active (Changing Switch #2 to N.C. turns the yellow indicator ON when the system is clear)

OFF

Output is inactive (Changing Switch #2 to N.O. turns the yellow indicator ON when the system is blocked)

#2

Steady Green

Power is ON and system is OK

Flashing Green Blanking is enabled

OFF

Power is OFF

Specifications

Supply Voltage and Current

Input Voltage: 12 to 30V dc (10% maximum ripple at
10% duty cycle)
Input Current: Less than 40 mA @ 24V dc and less
than 70 mA @ 12V dc (exclusive of load)

Supply Protection Circuitry

Protected against reverse polarity and transient over-
voltages

Sensing Beam

Visible red, 630 nm

Sensing Range

Retroreflective applications: 2 m (6.5 ft) using 25
mm (1 in) wide retroreflective tape
Diffuse applications: 400 mm (15.7 in) with 18% re-
flectivity gray card target

Sensing Height

4-channel models: 111 mm (4.4 in)
8-channel models: 240 mm (9.4 in)

Beam Spacing

28.6 mm (1.125 in)

Output Configuration

User-selectable via DIP switch:
1 open-collector PNP (current sourcing) or 1 open-col-
lector NPN (current sinking)

Sensing Resolution

See

Dimensions

on page 6 for Minimum Object De-

tection Zone
Retroreflective: 51 mm at 406 mm range, 100 mm at
2 m (2.0 in dia. at 16 in range, 3.9 in at 6.5 ft); see

Figure 2. Minimum object detection size (retroreflective
operation)

on page 2

Diffuse: 55 mm dia. at 400 mm range (2.16 in at 15.7
in range)

Indicators

Green LED: Power ON/OFF
Yellow LED: Output ON/OFF
Job Light (Diffused Green LED): Turned ON and OFF
by applying an external signal to the Job input (white
wire). The job lights will be active high or active low,
depending on DIP switch 4 selection.
Error Light (Diffused Red LED): Turned ON and OFF
by detection of an output event when job light is not
ON.

Adjustments

4 DIP switches, located behind access panel (default
setting is ON position)

Construction

Black painted aluminum housing; acrylic lenses; ther-
moplastic polyester end caps; thermoplastic elastomer
programming switch cover; stainless steel mounting
brackets and hardware

PVD Series Parts Verification Sensor

P/N 113230_web
Rev. E

www.bannerengineering.com - tel: 763-544-3164

5