5. Malfunctions

Danger!

Disconnect from the mains before starting
any service work or before removing the
cover. Afterwards attach the covers.

Malfunction:

Display illumination off.
Cause:
Power supply.
Remedy:
- Machine is plugged in?
- Main switch is on?
- Green overload switch (36) is pressed?
- Key switch on?
- Check the units fuse and the on-site circuit

breaker!

Malfunction:

Optical cutting line indicator does not function
after the machine has been moved to another
position.
Cause:
Phase direction wrong.
Remedy:
See "Installation and Power supply".

Malfunction:

Backgauge blocked.
Cause:
Motor is overloaded.
Remedy:
Press safety switch (37).

Malfunction:

Cut cannot be activated.
a) Cause:
Safety light beam is interrupted / dirty?
Remedy:
Remove any items and clean the sender.
b) Cause:
Measurement has not been reached correctly.
© LED "S" does not turn off.
Remedy:
Press

again.

c) Cause:
Size under 9 cm.
Remedy:
Put the false clamp in the provided holder.