Power supply – GBC EBA 721-05 LT User Manual

Page 6

Advertising
background image

- 6 -

EBA 721-05

01-03

01-04

2.2

Power supply

The name plate (23) is located at the rear of the
machine.
- Data stated on the name plate

- Voltage "V",
- Frequency "Hz",
- Power consumption "A"
must correspond to the values of the power supply
unit.

- Connect the machine to the mains.
- Earth wire must be available.

Standard machines are factory-set as follows:
- Voltage 400V (220V) 3 phase
- Frequency 50Hz (60Hz).

Machine does not function

- Machine (5) is switched on?
- Key-switch (4) on?
- Green overload switch (36) is pressed?
- Black overload switch (37) is pressed?
- Check on-site fuse.
If the machine still does not function then the
rotation must be reversed.
The machine is wired according to the IEC
standards. We recommend that alterations to the
rotary direction be made in the socket. It is also
possible to make alterations in the plug by
exchanging "L1" and "L2".

Danger!
Incorrect exchanging of the connections will

endanger the operator. This work must be
carried out by an electrician.

Advertising