3.1 Operating elements

(1) Safety two-handed control system
(2) Backgauge control
(3) Backgauge
(4) Key switch
(5) Main switch
(6) Paper knock-up block
(7) Clamp pressure adjustment
(8) Foot pedal
(9) Airtable switch
(10) Program number
(11) Program step
(12) LED "M" display memory
(13) LED "E" display eject
(14) LED "S" dsplay error indication
(15) Display cutting size
(16) Backgauge, backwards fast
(17) Electronical hand-wheel for fine adjustment
(18) Backgauge, forwards fast
(19) Clamp pressure
(20) Program keys
(21) Basic setting F1, F2, F3, eject
(22) Display false clamp plate
(23) Keypad with calculator
(24) Display impuls of backgauge movement
(25) Display in cm or inch
(26) Changeover cm-inch.

3.2 Start-up

- Position the main switch (5) to "I".
- Insert the key (4) for the control panel and turn to

the right.

- Press

button

© backgauge (3) moves to the

rear and searches for the reference position, wait
until a measurement is shown on the display.

Manual foot pedal

Pre-clamping can be performed using the foot pedal
(8) (e.g. folded stacks).

Cutting to a specified dimension

- Enter dimension on the numerical key

© LED "S"

(14) appears.

- Press

button

© dimension is approached,

LED "S" disappears.

- Insert paper and move by means of the paper

knock-up block to the backgauge (6).

- Release the cut (see 3.3 "Cutting activation").