Monitor Menu (2 of 2)

Item Field

Range

Access

Description

-22 to 266°F

(-30.0 to 130.0°C)

USER

INST

ADV

ROOM LOW

SECTION

A

Records the lowest room temperature. Press Up and
Down buttons to clear.
Note: This item is only available when there is at
least one active room sensor.

50 to 120°F, OFF

(10.0 to 49.0°C, OFF)

Default = OFF

ADV

ROOM HOT

SECTION

A

Provides a warning message when the room temperature
exceeds this setting.
Note: This item is only available when there is at
least one active room sensor.

OFF, 20 to 80°F

(OFF, -6.5 to 26.5°C)

Default = OFF

ADV

ROOM COLD

SECTION

A

Provides a warning message when the room temperature
drops below this setting.
Note: This item is only available when there is at
least one active room sensor.

0 to 9999 hr

INST

ADV

HEAT 1 RUN TIME

SECTION

F

Records the number of hours that first stage heat
runs. Press Up and Down buttons to clear.

0 to 9999 hr

INST

ADV

HEAT 2 RUN TIME

SECTION

F

Records the number of hours that second stage heat
runs. Press Up and Down buttons to clear.
Note: This item is only available when the thermostat
is used for two stage heating.

0 to 9999 hr

INST

ADV

COOL RUN TIME

SECTION

G

Records the number of hours that first stage cool
runs. Press Up and Down buttons to clear.
Note: This item is only available when the thermostat
is used for cooling.

0 to 9999 hr

INST

ADV

FAN RUN TIME

SECTION

I

Records the number of hours that the Fan runs. Press
Up and Down buttons to clear.
Note: This item is only available when Fan Mode is
set to 1 or 2, or Fan 1 Vent is set to On.

After the last item, the control returns to the first item in the menu.