tekmar 545 Thermostat Installation User Manual

Page 33

Advertising
background image

33 of 40

© 2008

D 545 - 07/08

Scenes

Section N

Scenes are a function that is available on the thermostat.

• To use the scene function, go to the Scene menu and

set the Scene setting to On.

Scenes are a method of changing the temperature throughout
an entire building from a single thermostat. A permanent
scene remains in place until another scene is selected.
When a temporary scene is selected (Scenes 6, 7, 8), a
timer counts down and when it times out, devices return
to the last permanent scene selected.

See the Scene table for details regarding the timing of
Scenes. There are a total of eight Scenes available.

• Default Scene: The default scene is Permanent 1. In a

typical installation, the thermostat will be set to follow
the scheduled event in the Permanent 1 scene.

• Factory Set Scenes: Scenes 2, 3 and 6 are factory set

and force the thermostat to the Away, Unoccupied or
the Occupied temperature respectively.

• Customizable Scenes: You can customize Scenes 1, 4,

5, 7, and 8 to either follow the scheduled event, or the
temperature can be forced to the Wake, Unoccupied,
Occupied, Sleep, or the Away temperature.

Note: If no schedule is available, the Scene menu selections
are limited to Occupied and Away

Scene

Description

Thermostat Operation

1

Permanent 1

Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away

2

Permanent Away 2

Away
DHW demands are ignored (applies to outdoor reset modules)
Setpoint demands operate (applies to outdoor reset modules)

3

Permanent Unoccupied 3 Unoccupied

4

Permanent 4

Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away

5

Permanent 5

Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away

6

Temporary Occupied 6

Occupied for 3 hours

7

Temporary 7

Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away for 4 hours

8

Temporary 8

Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away for 8 hours

Upstairs

Scheduled Event

Downstairs

Scheduled Event

Upstairs

UnOccupied

Downstairs

Scheduled Event

for

4hr

Scene 1

Scene 7

70°F

70°F

62°F

70°F

Master Bedroom

Scheduled Event

Guest Bedroom

UnOccupied

Master Bedroom

Scheduled Event

Guest Bedroom

Scheduled Event

Scene 1

70°F

62°F

70°F

70°F

Scene 4

Example 1:
A house is normally in scene Permanent 1. There is a
master bedroom that operates on a schedule and there is
a guest bedroom that is normally set to Unoccupied. When
a guest arrives, the scene changes to Permanent 4. Scene
4 has been pre-programmed to change the guest room to
operate on the schedule.

Master bedroom thermostat:
Scene Permanent 1 is set to Schedule.
Scene Permanent 4 is set to Schedule.
Guest bedroom thermostat:
Scene Permanent 1 is set to Unoccupied.
Scene Permanent 4 is set to Schedule.

Example 2:
A house is normally in scene Permanent 1. There are
bedrooms upstairs and the entertainment area is downstairs.
The occupants are entertaining guests for an evening and
scene Temporary 7 is selected. This causes the upstairs
thermostats to operate at the Unoccupied temperature and
the downstairs to operate and the Occupied temperature
for four hours.

Upstairs thermostats:
Scene Permanent 1 is set to Schedule.
Scene Temporary 7 is set to Unoccupied.
Downstairs thermostats:
Scene Permanent 1 is set to Schedule.
Scene Temporary 7 is set to Occupied.