Cdv series direct vent gas fireplace, Rear wall vent installations - 45° flex vent pipe – Vermont Casting 36CDVRRN User Manual

Page 14

Advertising
background image

14

CDV Series Direct Vent Gas Fireplace

20010175

Rear Wall Vent Installations -

45° Flex Vent Pipe

NOTE: Under no circumstances can ridged pipe or
a rigid 45° elbow be used. The 7TCDV45KT must be
used in a corner installation. The corner placement
dimensions on Page 4 of the manual must be ad-
hered to! Figures 16 & 18 show general installations.
Refer to instructions below for a detailed description
of installation.
1. Determine where the termination is to be in-

stalled. Locate the center of the hole 29¹⁄₂”
(749 mm) off the floor. (Fig. 16)

NOTE: The location of the termination hole must be

adhered to!

2. Install the firestop as shown on Page 12.
3. Remove the flex vent and extend the flex vent out

to its longest length.

4. Bend the tab on the back of the fireplace up. (Fig.

14)

5. Insert the collar on the flex vent that has the twist

lock embosses on it onto the collar of the fire-
place. Twist the collar to “lock it” onto the fire-
place. Run a screw through the tab and into the
collar to secure the collar onto the fireplace.

6. Bend the flex pipe up 90° as close to the fireplace

as possible. (Fig. 17)

7. Slide the fireplace partially into the corner and,

while holding the vertical portion of the flex vent
pipe, grab the exposed end collar and bend it
down to the height of the opening in the wall.

8. While pushing the unit in place, slide the collar

through the firestop. NOTE: It may be necessary
to trim some material off of the collar. The col-
lar is made long to accommodate brick finished
houses. (Fig. 19)

9. Secure the collar in place by running a screw

through the tab in the firestop and through the
collar.

10. Slide the termination into the collar and secure

with the 4 screws provided. (Fig. 19)

FP1473

corner flex install

4/04 djt

CL

to Floor

29���”

(749 mm)

Termination

Flex Section

Appliance

Collars

FP1473

Fig. 16 Grasp the vent pipe close to the collar and bend to
45° angle. Do not exceed 45°.

������
��������������
�����

Fig. 17 Bend flex pipe up 90° as close to fireplace as pos-
sible.

FP1604

������
�������������������
����

Do Not Exceed

45° Bend

Corner

Framing

Termination

FP1606

Fig. 18 Rear view of corner installation.