General venting – Vermont Casting 36CDVRRN User Manual

Page 9

Advertising
background image

9

CDV Series Direct Vent Gas Fireplace

20010175

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current CSA
C22.1 Canadian Electrical Code.

For USA installations follow local codes
and the national electrical code ANSI/
NFPA No. 70.

It is strongly suggested that wiring of the
Electrical Junction Box be carried out by a
licensed electrician.

Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.

120V Electrical Hook Up

The electrical junction box has been fitted standard on
this model to allow for the easy connection of an op-
tional fan kit.
To connect the electric box to the house electrical sup-
ply follow the steps below.
1. Unscrew the retaining screw holding the electric

cover to the outside of the unit. (Fig. 7)

2. Remove the knockout from the electric cover plate.
3. Insert the wire connector through the hole in the

electric cover plate and secure.

FP1597

Fig. 7 Electric receptacle.

FP1597

receptacle install

12/05

OUTSIDE

INSIDE

BACK OF UNIT

Electric Receptacle

Electric Receptacle

Cover Plate

4. Insert the house wire through the connector on the

cover plate.

5. Secure the wires from the receptacle to the incoming

line.

6. The receptacle has four wires connected to it. The

receptacle is set up for a split system. The top plug
of the receptacle is wired separately from the bottom
one.

7. Green is ground. White is neutral, Black and red are

line voltage to each plug on the receptacle.

Your fireplace is approved to be vented either through
the side wall, or vertically through the roof.

Only CFM Corporation venting components specifi-
cally approved and labelled for this fireplace may be
used.

Vent terminations shall not be recessed into a wall or
siding.

Horizontal venting which incorporates the twist lock
pipe must be installed on a level plane without an
inclining or declining slope.

Horizontal venting which incorporates the use of flex
venting shall have an inclining slope from the unit of
1” (25 mm) per 24” (610 mm).

General Venting

There must not be any obstruction such as bushes,
garden sheds, fences, decks or utility buildings within
24” (610mm) from the front of the termination hood.
Do not locate termination hood where excessive snow
or ice build up may occur. Be sure to check vent termi-
nation area after snow falls, and clear to prevent ac-
cidental blockage of venting system. When using snow
blowers, make sure snow is not directed towards vent
termination area.
Location of Vent Termination
It is imperative the vent termination be located observ-
ing the minimum clearances as shown on the next
page.
*Check with local codes or in absence of same with
CSAB149.1 Installation Codes (1991) for Canada or fol-
low the current National Fuel Gas Code, ANSI Z223.1/
NFPA 54 for installations in the USA.