Optional accessories available – Vermont Casting 36CDVRRN User Manual

Page 37

Advertising
background image

37

CDV Series Direct Vent Gas Fireplace

20010175

FK12
This auxiliary fan system increases the efficiency of the
circulation of the heating air.
The FK12 Fan Assembly is a fixed speed fan system
and does not allow for variable speed control.
Specifications
115 Volts / 60 Hz / 56 Watts.
Maintenance
The fan itself does not require regular maintenance,
however periodic cleaning of the fan and the
surrounding area is required.
Check the area under the control door (lower louvre
assembly) and in front of the fan and wipe or vacuum
this area at least once a month during the operating
season.
Installation
The fan assembly is supplied fully wired eliminating
the need for a licensed electrician to carry out the
installation.
1. Remove the lower Louvre assembly. Move the

fan & bracket assembly around the gas valve and
lines to locate the unit against the back wall of the
appliance, resting on the base.

2. With the protective cover removed from the self-

adhesive ‘Velcro’ strips apply mild pressure to the
fan & bracket unit to secure the strips to the metal
panels. No further securing is required.

3. Power to the fan can be supplied by plugging the

supplied lead into a conveniently located wall socket
or by using the receptacle in the bottom of the unit.

Optional Accessories Available

Fan Kits

FP1602

FK12

fan install

12/05

Fan

Gas Lines

Valve

FP1602

Fig. 64 FK12 fan placement.

Receptacle

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electric Code.

For USA installations follow the local codes
and the national electrical code ANSI/NFPA
No. 70.
Should this fan require servicing or repair
the power supply must be disconnected.

Any electrical rewiring of this fan must be
done by a licensed electrician.

Wiring Instructions

Remote Controls

Optional remote control units are available to control
different functions of the appliances.

Model

Function/s Controlled

RCI

ON/OFF

RC2

ON/OFF and Temperature

IMTFK

Wall mounted thermostat control

(must be used in bedroom installations)