Maintenance – Vermont Casting 36CDVRRN User Manual

Page 34

Advertising
background image

34

CDV Series Direct Vent Gas Fireplace

20010175

Burner and Burner Compartment

It is important to keep the burner and the burner
compartment clean. At least once per year the logs and
lava rock/ember material should be removed and the
burner compartment vacuumed and wiped out. Remove
and refit the logs as per the instructions in this manual.

Always handle the logs with care as they
are fragile and may also be hot if the
fireplace has been in use.

FK12 Fan Assembly

The fan unit requires periodic cleaning. At least once
per month in the operating season open the lower
louvre panels and wipe or vacuum the area around the
fan to remove any build up of dust or lint.

Cleaning the Standing

Pilot Control System

The burner and control system consist of:

burner

gas orifice

pilot assembly

thermopile

millivolt gas valve

Most of these components may require only an
occasional checkup and cleaning and some may
require adjustment. If repair is necessary, it should
be performed by a qualified technician.
1. Turn off pilot light at gas valve.
2. Allow fireplace to cool if it has been operating.
3. Remove window frame assembly. (Refer to Window

Frame Assembly Removal section.)

4. Remove logs.
5. Vacuum burner compartment especially around

orifice primary air openings.

6. Visually inspect pilot. Brush or blow away any dust

or lint accumulation.

7. Reinstall logs.
8. Ignite pilot - Refer to Lighting Instructions.
9. Reinstall window frame assembly.

To obtain proper operation, it is imperative that the pilot
and burner’s flame characteristics are steady, not lifting
or floating.
Typically, the top 3/8” to 1/2” of the thermopile should
be engulfed in the pilot flame. (Refer to Page 59, Figure
61)
To adjust pilot burner: (by qualified service technician)
1. Remove pilot adjustment cap
2. Adjust pilot screw to provide properly sized flame.
3. Replace pilot adjustment cap.
The primary air shutter is set at factory and should
only be adjusted, if necessary, by a qualified service
technician.

Maintenance

Advertising