Tweco 15XC CE Merlin PAK User Manual
Page 29
Advertising

Manual 0-2529
2 - 7
INSTALLATION
Figure 2-D Input Voltage Connections and Bus Bar Configuration
Input Power
Filter PC Board
and Bracket
Primary Power
Cable
Strain Relief
Fitting
Input Ground
Connection
A-00896
L1
L2
L3
INPUT
VOLTAGE
380/415
VAC
BUS BAR
CONNECTIONS
L1-3, 1-2
L2-8, 6-7
L3-13, 11-12
Table 2-A Line Voltages, Circuit Protection and Recommended Wire Size
(Based on Table 310-16, 1987 National Electric Code).
Voltage
Power Input
Current
Frequency
Phase
Recommended
(Volts)
(kVA)
(Amps)
(Hz)
Fuse Size
Wire Size
380
29
44
50
3
50 amps
AWG 8
415
29
40
50
3
45 amps
AWG 8
380/
415VAC
L1
L3
L2
Input Voltage Connector
Installation Detail
Input
Connector
Input Power Cable
(One Line)
Slotted Screw
A-00908
PC Board
Power Stud
Flat Washer
Conical Spring
Washer
Hex Locking
Nut