Tweco 15XC CE Merlin PAK User Manual

Page 94

Advertising
background image

SERVICE

4 - 22

Manual 0-2529

1. Voltage selection bus bars

connected incorrectly

2. One leg of three-phase

primary connected to
chassis ground

3. Main transformer shorted

1. Shorted input diode

(D1-D6)

2. Switching transistor (Q1)

shorted to heatsink

3. Shorted input capacitor

(C7-C12)

4. Shorted diode (D11-D14)

5. Faulty voltage selection

board

6. Faulty main contactor (W1

or W2)

1. Unit overheated

2. Faulty thermal sensor

(TS1, TS2, or TS3)

3. Faulty logic board

4. Faulty LED/current

control board

1. RUN/SET/PURGE switch

set to PURGE, secondary
mode switch set to GAS
secondary

2. Gas pressure set too low

1. Check and correct if

necessary.

2. Rewire input cable (see

Electrical Connections,
page 2-6)

3. Replace main transformer

1. See test D (page 4-29) and

replace diode if necessary

2. Replace Q1, check heat-

sink for possible damage,
perform test D (page 4-29)

3. Replace capacitor if

necessary

4. Check for proper 3-phase

power at input terminal
board, check diodes (see
test D, page 4-29)

5. If W1 and W2 come on

simultaneously replace
board.

6. Check and replace contac-

tor if necessary

1. Clean radiator and check

for obstruction.

2. See test E (page 4-30) and

replace sensors if neces-
sary

3. See test E (page 4-30) and

replace board if necessary

4. See test E (page 4-30) and

replace board if necessary

1. Normal operation (purges

plasma line only, secon-
dary flow switch is not
satisfied)

2. Adjust pressure

TROUBLE

POSSIBLE CAUSE

REMEDY

C. Fuse blown at disconnect

when primary power is
connected

D. Fuse blown at disconnect

when main contactor (W1
or W2) closes

E. TEMP indicator lit (red).

F. No GAS indicator