11 troubleshooting guide, 11 troubleshooting guide -21 – Tweco 15XC CE Merlin PAK User Manual

Page 93

Advertising
background image

Manual 0-2529

4 - 21

SERVICE

4.11 TROUBLESHOOTING GUIDE

TROUBLE

POSSIBLE CAUSE

REMEDY

A. No front panel LED

indicators lit. Fan and
pump off.

B. AC indicator on. Fan and

pump off.

(Causes 6 and 7 are only
for systems having re-
mote control panel)

1. No primary power. See

also Steps C and D (page
4-22)

2. Blown fuse (F2)

3. Faulty ON/OFF switch

(SW1)

4. Faulty voltage selection

board

1. No primary power See

also Steps C and D (page
4-22)

2. Blown fuse (F1 or F2)

3. Faulty ON/OFF switch

(SW1)

4. Faulty voltage selection

board

5. Faulty motor contactor

(MC1 or MC2)

6. Faulty switching control

board (relay K1 not ener-
gized to bypass remote E-
stop function)

7. Remote cable plugged into

J15; remote control panel
not connected on other
end of cable

8. Remote panel E-stop

button activated (or
faulty)

1. Check for proper three-

phase power at input
terminal board

2. Check and replace fuse if

necessary

3. Disconnect primary

power. Check each section
for continuity. Replace
switch if necessary

4. See test A (page 4-27) and

replace board if necessary

1. Check for proper three-

phase power at input
terminal board

2. Check and replace fuse if

necessary. See Test B
(page 4-28)

3. Disconnect primary

power. Check each section
for continuity. Replace
switch if necessary

4. See test A (page 4-27) and

replace board if necessary

5. See test C (page 4-29) and

replace contactor if neces-
sary

6. See test C. part 3 (page 4-

29)

7. Remove cable plug from

J15 or connect remote
panel correctly

8. Twist button clockwise to

release. If necessary, check
for continuity from J37-35
to J37-36