Manual 0-2529

4 - 25

SERVICE

TROUBLE

POSSIBLE CAUSE

REMEDY

L. No pilot arc. DC indicator

on, PCR not energized

M. No pilot. PILOT indicator

on, PCR energized, little
or no spark at spark gap
points

N. Weak or sputtering pilot.

HF stays on during pilot

O. No pilot. PILOT indicator

on, strong spark visible at
spark gap points

1. Faulty logic board, switch-

ing board, or shunt amp
board

1. Faulty PSR relay

2. Faulty HF transformer

(T3)

3. Faulty capacitor (C31)

1. Plasma gas pressure too

high

2. Low OCV (normal 290-

350) caused by improper
connection of voltage
selection bus bars

3. Low OCV caused by

faulty voltage selection PC
board

1. Electrode shorted against

tip

2. Shorted torch head

3. Faulty capacitor (C25)

4. Broken conductor in torch

lead

5. Shorted torch lead

6. Dirty or wet torch lead

1. See test L (page 4-34)

1. Check for faulty NC

contacts or poor relay
connection in socket

2. Check and replace if

necessary.

3. Check capacitor and

replace if necessary

1. Adjust pressure

2. Check input voltage

connections (page 2-6)

3. If three-phase input

voltage is within the
lower half of range (see
Input Voltage Selection,
page 4-17), D18 on voltage
selection PC board should
not be lit. If D18 is lit,
replace the voltage selec-
tion PC board.

1. Thread electrode securely

into torch head

2. Check and replace if

necessary

3. Check and replace if

necessary

4. Check and replace if

necessary

5. Check and replace if

necessary

6. Clean and dry torch lead