Figure 4-D Machine Torch Head Replacement

Make sure the insulating tab completely separates the
coolant supply lead (negative) from the plasma, secondary,
and coolant return leads.

7. Replace the mounting assembly onto the torch head.

8. Secure the shielded inner sleeving to the leads with

electrical tape. Position the end of the sleeving a few
inches back from the mounting assembly.

9. Position the nylon outer sleeving over the shielded

inner sleeving. The shielded inner sleeving must be
completely covered by the outer sleeving to avoid any
possible contact with the mounting assembly.

10. Secure the nylon outer leads sleeving to the leads with

electrical tape. Position the tape close to the back of the
mounting assembly.

CAUTION

A-00961

Torch Head

Insulating Tape

Coolant Return

Lead

Plasma

Lead

Electrical

Tape

Secondary

Lead

Coolant Supply

Lead

Mounting

Assembly

Electrical

Tape

Shielded Inner

Leads Sleeving

Nylon Outer

Leads Sleeving