13 dpc-3000 status codes – Tweco 400 Ultra-Cut XT Plasma Cutting System User Manual

Page 104

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

4-26

OPERATION

Manual 0-5297

Group 5 - Shorted Solenoid Faults

5-1

Sol 1 – H35 Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-2

Sol 2 – Oxygen Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-3

Sol 3 – Air Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-4

Sol 4 – Nitrogen Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-5

Sol 5 – Aux Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-6

Sol 6 – Oxygen Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-7

Sol 7 – Air Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-8

Sol 8 – Nitrogen Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-9

Sol 9 – H2O Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-10

Sol 10 – Oxygen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-11

Sol 11 – Air Preflow

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-12

Sol 12 – Nitrogen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-13

Sol 13 – Argon Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-14

Sol 14 – Air Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-15

Sol 15 – Nitrogen Mark-

ing

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

* Communication faults shown on the DMC can be caused by the device on the other end of the communication line.

Before assuming the DMC is at fault see if either the CCM or the DPC are showing any codes that might indicate they are at

fault instead.

4.13 DPC-3000 Status Codes

DPC Status Code Key

Group 1 - DPC

Code

Message

Cause/Remedy

1-1

Plasma Disabled

Enable Plasma; DMC Power Supply input fuse F1 blown (no lights on DMC); Defective DMC

Power Supply (E-Stop relay). Defective DPC Power Supply (E-Stop relay). Defective DPC control

PCB

1-2

24 VDC fault

Check /replace DPC power supply output fuse (F2); Defective DPC power supply; Replace DPC

control PCB

1-3

+12 VDC fault

Check /replace DPC power supply; Replace DPC control PCB

1-4

-12 VDC fault

Check /replace DPC power supply; Replace DPC control PCB

1-5

5 VDC fault

Check /replace DPC power supply; Replace DPC control PCB

1-6

Analog Reference fault

Replace DPC Control PCB

1-7

ADC voltage fault

Replace DPC Control PCB

1-8

Reserved

1-9

Valve not configured

Resend process from TSC 3000 / CNC

1-10 DPC is locked

Process loading, wait until finished

Group 2 - Control Communication

2-1

Acknowledge error

Fiber optic cable; DPC Control PCB

2-2

Timeout

Communication loss: Check DMC codes; if DMC 2-1 check DPC to DMC Fiber optic cable, DMC

4-2 check DMC to CCM fiber-optic cable.; DPC Control PCB; DMC Control PCB; CCM.

2-3

Protocol

Program firmware fault, consult factory

2-4

Bus off

Fiber optic cable; DPC Control PCB

2-5

Physical

Fiber optic cable; DPC Control PCB

Advertising