7.04 Torch Consumables Installation

Art # A-03887

WARNINGS

Do not install consumables into the Cartridge

while the Cartridge is attached to the Torch Head.

Keep foreign materials out of the consumables and Cartridge.

Handle all parts carefully to avoid damage,

which may affect torch performance.

1. Install the consumables as follows:

Cartridge Covers
Upper O-Ring
on Torch Tip

Shield Cap Protrudes
0.063-0.083" (1.6 - 2.1 mm)

Electrode

Plasma Gas
Distributor

Tip

Shield Gas
Distributor

Shield Cap

Upper O-Ring

on Tip

1: Stack Parts

2: Press Cartridge onto Stacked Parts

4: Check Shield Cap Protrusion

Art # A-04716

No Gaps

Between Parts

3: Thread Shield Cup onto Cartridge

Shield Cap

Shield Cup

2, Remove the Removal Tool from the Cartridge and install the assembled Cartridge onto the Torch Head.