06 specifications & electrical requirements – Tweco 400 Ultra-Cut XT Plasma Cutting System User Manual

Page 20

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

2-2

SPECIFICATIONS

Manual 0-5297

2.06 Specifications & Electrical Requirements

100 Amp System

Ultra-Cut 100 XT™ Specifications & Design Features

Max OCV (U0)

400 vdc

Minimum Output Current

5 Amps

Max Output Current

100 Amps

Output Voltage

60 - 180 vdc

Duty Cycle Rating

100% @ 100A, 200V, (20kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 100 A DC Output

Cooling

Coolant and Forced Air (Class F)

200 Amp System

Ultra-Cut 200 XT™ Specifications & Design Features

Max OCV (U0)

400 vdc

Minimum Output Current

5 Amps

Max Output Current

200 Amps

Output Voltage

60 - 180 vdc

Duty Cycle Rating

100% @ 200A, 200V, (40kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 200 A DC Output

Cooling

Coolant and Forced Air (Class F)

300 Amp System

Ultra-Cut 300 XT™ Specifications & Design Features

Max OCV (U0)

400 vdc

Minimum Output Current

5 Amps

Max Output Current

300 Amps

Output Voltage / IEC

60 - 180 vdc / 60 - 200 vdc

Duty Cycle Rating

100% @ 300A, 200V, (60kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 300 A DC Output

Cooling

Coolant and Forced Air (Class F)

400 Amp System

Ultra-Cut 400 XT™ Specifications & Design Features

Max OCV (U0)

400 vdc

Minimum Output Current

5 Amps

Max Output Current

400 Amps

Output Voltage

60 - 200 vdc

Duty Cycle Rating

100% @ 400A, 200V, (80kW),

Ambient Temperature

for Duty Cycle Rating

104F° (40°C)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 400 A DC Output

Cooling

Coolant and Forced Air (Class F)