Section 4: operation, 01 power supply control panel, 02 system operation – Tweco 400 Ultra-Cut XT Plasma Cutting System User Manual

Page 79

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

Manual 0-5297

OPERATION

4-1

SECTION 4: OPERATION

4.01 Power Supply Control Panel

Art # A-11541_AB

AC Indicator

Temp Indicator

Gas Indicator

DC Indicator

A/

Status Indicator

A/

AC Power Lamp

Indicates unit has passed the input power tests and AC power is being supplied to the inverter modules via the

input contactor when the ON/OFF switch is in ON position.

TEMP Lamp: Normally OFF. Lamp will come ON when the internal temperature sensors detect temperatures

above normal limits. Let the unit cool before continuing operation.

GAS Lamp: Flashing during start up gas purge/pump priming, then steady whenever gas is flowing. Indicates

adequate gas pressure and coolant flow for operation.

DC Lamp: Indicates the power supply is generating output DC voltage.

A/

Status Indicator: Shows CCM code version on start up followed by the Current Control setting and

system status. Refer to Section 4.05 and Status Code Section for details.

Rear Panel AC Power Lamp

Indicates AC power is present inside the unit

4.02 System Operation

This section contains operating information which is specific to the power supply.

WARNING

Review the safety precautions in Section 1.
If the power supply cord has a plug or is not permanently connected to power, be sure the power to the

outlet is disconnected when inserting the plug into the outlet.
Disconnect primary power at the source before assembling or disassembling power supply, torch parts,

or torch and leads assemblies, or adding coolant.
It is not enough to simply move the ON/OFF switch on the unit to OFF position when cutting operations

have been completed. Always open the power supply disconnect switch five minutes after the last cut

is made.

Advertising