23 install remote arc starter – Tweco 400 Ultra-Cut XT Plasma Cutting System User Manual

Page 64

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

3-36

INSTALLATION

Manual 0-5297

3.23 Install Remote Arc Starter

Site Location

Select a clean, dry location with good ventilation and adequate working space around all components.

Review the safety precautions in the front of this manual to be sure that the location meets all safety requirements.

Interconnecting cables and hoses attach to the Arc Starter. There must be adequate space around the Arc Starter for

these connections without excessive kinking or bending.

Mounting Dimensions

NOTE

Height not shown is 7.375” ( 187mm )

38.10mm

1.50in

190.50mm

7.50in

50.80mm

2.00in

203.20mm

8.00in

50.80mm

2.00in

38.10mm

1.50in

Art # A-12058

Installation

The Remote Arc Starter must be installed in a suitable location near the torch head.

If the Arc Starter is mounted

to a gantry or to any other support subject to motion or vibration, fasten the Arc Starter to the support securely.

1. Loosen, but do not remove, the lower screws securing the cover to the Arc Starter. Remove the upper screws

securing the Cover Panel to the Arc Starter.

NOTE

A ground wire connects the cover to the Arc Starter base. This wire must remain in place.