Tweco 400 Ultra-Cut XT Plasma Cutting System User Manual

Page 45

Advertising
background image

ULTRA-CUT 100 XT/200 XT/300 XT/400 XT

Manual 0-5297

INSTALLATION

3-17

3.14 Connect TSC-3000 Cable and DMC-3000 Fiber Optic Cable to CCM

1. Remove the bottom plastic plug in the CCM at the rear of the Power Supply.

COOLANT

RETURN SUPPLY

Art # A-11991

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

USER INPUT

HEIGHT CONTROL

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB4 - 5A 120 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

J55 - GCM

J15 - CNC

J59 - RAS

J70 - HE

J54 - TSC /COMM

TSC-3000 Cable

DMC-3000 Fiber

Optic Cable

CAUTION

Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into tight-

radius turns.

2. Remove outer thin nut from through hole protector at one end of Fiber Optic Cable (L) that connects between

the CCM portion of the Power Supply and the DMC-3000.

3. Feed the Fiber Optic Cable plug and wires through the hole where the plastic plug was removed labeled

GCM/DMC and slide the thin nut back over the Fiber Optic Cable.

4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside

and out.

Advertising