Fabricator 211i introduction, 09 specifications – Tweco 211i Fabricator User Manual

Page 28

Advertising
background image

FABRICATOR 211i

INTRODUCTION

INTRODUCTION

2-4

Manual 0-5157

2.09 Specifications

Description

Fabricator 211i Multi Process 3 in 1 Welder

Power Source Part No.

W1004200

Power Source Dimensions

H17.12" x W10.47" x D 24.29" (435mm x 266mm x D617mm)

Power Source Mass

57.3lb (26kg)

Cooling

Fan Cooled

Welder Type

Multi Process Welding System

Applicable Standard

CSA E60974-1-00 / UL60974-1 / IEC 60974-1

Number of Phases

Single Phase

Nominal Supply Voltage

208/230 VAC ± 10%

115VAC± 10%

Nominal Supply Frequency

50/60Hz

50/60HZ

Welding Current Range

MIG Mode

STICK Mode

TIG Mode

10-210 Amps

10-200 Amps

10-200 Amps

10-140 Amps

10-110 Amps

10-150 Amps

Wirefeed Speed Range

100 - 600 IPM

100 - 400 IPM

MIG Welding Voltage Range

14.5 - 24.5V DC

14.5 - 19V DC

Nominal OCV

70V DC

Effective Input Current (I

1eff

)

for MIG (GMAW/FCAW)

for STICK (SMAW)

for LIFT TIG (GTAW)

14.4A/11.2A

16.8A/15.8A

11.7A/11.5A

15.5A

17.8A

17.4A

Maximum Input Current (I

1max

)

for MIG (GMAW/FCAW)

for STICK (SMAW)

for LIFT TIG (GTAW)

32.2A/25.0A

33.6A/31.6A

23.3A/22.9A

24.5A

30.1A

29.4A

Single Phase Generator Requirement

7.5 kVA

*3.7 kVA

MIG (GMAW/FCAW) Welding Output, 104°F, 10 min.

210A @ 20%,24.5V

122A @ 60%, 20.1V

95A @ 100%, 18.8V

110A @ 45%,19.5V

99A @ 60%, 19.0V

77A @ 100%, 17.9V

STICK (SMAW) Welding Output,1040°F, 10 min.

200A @ 25%,28.0V

130A @ 60%, 25.2V

101A @ 100%, 24.0V

110A @ 35%,24.4V

90A @ 60%, 23.6V

70A @ 100%, 22.8V

TIG (GTAW) Welding Output, 104°F, 10 min.

200A @ 25%,18.0V

130A @ 60%, 15.2V

101A @ 100%, 14.0V

150A @ 35%,16.0V

115A @ 60%, 14.6V

90A @ 100%, 13.6V

Open Circuit Voltage

70 V

Protection Class

IP23S

Table 2-1: Fabricator 211i Specifications

Note 1: The Effective Input Current should be used for the determination of cable size & supply requirements.

Note 2: Motor start fuses or thermal circuit breakers are recommended for this application. Check local require-

ments for your situation in this regard.

Note 3: Generator Requirements at the Maximum Output Duty Cycle.

* Some 115 VAC, 15 amp/20 amps electrical outlets fitted with GFCI (Ground Fault Circuit Interrupt) protection

against a nuisance trip with this equipment due to worn or out of tolerance components in the GFCI. In such cases

have the 115 VAC, 15 amp/20 amp FGCI electrical outlet replaced by a qualified electrical trades person.

Advertising