INSTALLATION/SETUP

FABRICATOR 211i

Manual 0-5157

3-3 INSTALLATION/SETUP

WARNING

An electrical shock or fire hazard is probable if the following electrical service guide recommendations are

not followed. These recommendations are for a dedicated branch circuit sized for the rated output and duty

cycle of the welding Power Source.

50 / 60 Hz Single Phase Supply

Supply Voltage

208/230V AC

115V AC

Input Current at Maximum Output

32 Amps

30 Amps

Maximum Recommended Fuse* or Circuit Breaker Rating

* Time Delay Fuse, UL class RK5. Refer to UL248

50 Amps

30 Amps

Maximum Recommended Fuse^ or Circuit Breaker Rating

^Normal Operating, UL class K5. Refer to UL248

50 Amps

30 Amps

Minimum Recommended Cord Size

12 AWG

12 AWG

Maximum Recommended Extension Cord Length

50 ft

25 ft

Minimum Recommended Grounding Conductor Size

12 AWG

12AWG

Table 3-1: Electrical Service Guide

CAUTION

The time-delay fuses or circuit breaker of an individual branch circuit may have nuisance tripping when

welding with this product due to the amperage rating of the time-delay fuses or circuit breaker.

Art# A-11240

Primary Power Cable

115

115

V,

V,

20A, 1Ø

15A, 1Ø

208/230V, 50A, 1Ø

The Adapter enable

connection to all these

power outlets

115 VAC Adapter

Figure 3-2: Electrical Input Connections