Fabricator 211i installation/setup – Tweco 211i Fabricator User Manual

Page 36

Advertising
background image

FABRICATOR 211i

INSTALLATION/SETUP

INSTALLATION/SETUP

3-4

Manual 0-5157

3.05 Electromagnetic Compatibility

!

WARNING

Extra precautions for Electromagnetic Compatibility may be required when this Welding Power Source is

used in a domestic situation.

A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions.

If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to

resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as

simple as earthing the welding circuit, see NOTE below. In other cases it could involve constructing an electromag-

netic screen enclosing the Welding Power Source and the work, complete with associated input filters. In all cases,

electromagnetic disturbances shall be reduced to the point where they are no longer Troublesome.

NOTE

The welding circuit may or may not be earthed for safety reasons. Changing the earthing arrangements

should only be authorized by a person who is competent to assess whether the changes will increase the

risk of injury, e.g. by allowing parallel welding current return paths which may damage the earth circuits

of other equipment.

B. Assessment of Area
Before installing welding equipment, the user shall make an assessment of potential electromagnetic problems in the

surrounding area. The following shall be taken into account.
1. Other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the welding

equipment.

2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of industrial equipment.
5. The health of people around, e.g. the use of pace-makers and hearing aids.
6. Equipment used for calibration and measurement.
7. The time of day that welding or other activities are to be carried out.
8. The immunity of other equipment in the environment: the user shall ensure that other equipment being used in

the environment is compatible: this may require additional protection measures.

The size of the surrounding area to be considered will depend on the structure of the building and other activities that

are taking place. The surrounding area may extend beyond the boundaries of the premises.
C. Methods of Reducing Electromagnetic Emissions

1. Electricity Supply
Welding equipment should be connected to the Electricity Supply according to the manufacturer’s recommendations.

If interference occurs, it may be necessary to take additional precautions such as filtering of the Electricity Supply.

Consideration should be given to shielding the supply cable of permanently installed welding equipment in metallic

conduit or equivalent. Shielding should be electrically continuous throughout its length. The shielding should be

connected to the Welding Power Source so that good electrical contact is maintained between the conduit and the

Welding Power Source enclosure.