INSTALLATION/SETUP

FABRICATOR 211i

Manual 0-5157

3-27 INSTALLATION/SETUP

E. Fit the welding grade shielding gas regulator/flowmeter to the shielding gas cylinder (refer to Section 3.06) then

connect the shielding gas hose from the TIG torch to the regulator/flowmeter outlet. Note that the TIG torch shield-

ing gas hose is connected directly to the regulator/flowmeter. The power source is not fitted with a shielding gas

solenoid to control the gas flow in LIFT TIG mode therefore the TIG torch will require a gas valve.

!

WARNING

Before connecting the work clamp to the work and inserting the electrode in the TIG Torch make sure the

Electricity Supply is switched OFF.
Secure the welding grade shielding gas cylinder in an upright position by chaining it to a stationary support

to prevent falling or tipping.

CAUTION

Remove any packaging material prior to use. Do not block the air vents at the front or rear of the Welding

Power Source.
Loose welding terminal connections can cause overheating and result in the male plug being fused in the

terminal.

F. Switch the LOCAL/REMOTE switch inside the

wire feed compartment to LOCAL to use the

Power Sources Amperage control or REMOTE

for remote amperage using a Foot Control.

Positive Welding

Terminal (+)

Negative Welding

Terminal (-)

Work Lead

TIG Torch

TIG Remote Control

Art # A-11246_AB

Connect to shielding gas

regulator/flow gauge.

Secure the gas cylinder

in an upright position by

chaining it to a stationary

support to prevent falling

or tipping.

Note: A Tweco 26V TIG torch with

an 8 pin plug must be used to turn the

weld current on/off via the TIG torch trigger

switch to TIG weld OR a Tweco Foot

Control with an 8 pin plug must be used to

turn the weld current on/off as well as

providing remote control of the weld current.

Figure 3-22: Setup for TIG Welding