Tweco 550i Transmig User Manual

Page 26

Advertising
background image

TRANSMIG 350i, 450i, 550i

INSTALLATION, OPERATION AND SETUP 3-6 Manual 0-5205

5. Inch Button

The INCH button is active in 10 PIN GMAW/FCAW mode (MIG) only.

Press and hold the INCH button to inch the wire in the Wirefeeder (Active in 10 Pin mode only).

6. Local / Remote Button

The REMOTE button is used to select REMOTE or LOCAL mode of operation.

The REMOTE button is used only when a remote control device (such as a TIG torch with remote current

control, or a Wirefeeder) is fitted to the unit via the remote control socket (items 5 & 6). When the REMOTE

button is in the remote position, the unit will detect a remote device and work accordingly

When in the local mode, the unit will not detect the remote device and will operate from the power source

controls only. Note that the trigger will operate at all times on the remote control socket irrespective of

the position of the local remote switch (ie in both local and remote modes).

Should a remote device be connected and the remote/local switch set to remote, the maximum setting

of the power source will be determined by the respective front panel control, irrespective of the remote

control device setting. As an example, if the output current on the power source front panel is set to 50%

and the remote control device is set to 100%, the maximum achievable output from the unit will be 50%.

Should 100% output be required, the respective front panel control must be set to 100%, in which case

the remote device will then be able to control between 0-100% output.

7. 10 PIN / 19 PIN Remote Button

The REMOTE button is used to select 10 PIN, 19 PIN, mode of operation when the REMOTE button ( item

13) is in REMOTE mode.

When in 10 PIN Remote mode, the 10 PIN control socket is active and remote voltage or current / wire-

speed controls will be active.

The 10 PIN Remote mode is only available in GMAW/FCAW (Mig) and GTAW (Lift Tig) modes only.

When in 19 PIN Remote mode, the 19 PIN control socket is active and remote voltage controls will be active.

The 19 PIN Remote mode is only available in GMAW/FCAW (Mig) mode only.

NOTE

When operating a 10 pin Wirefeeder in remote mode, the maximum output is determined by the

settings of the power source (in local mode). This is done such that the maximum output available

at the wirefeeder can be restricted to a preset level. This preset level must be selected whilst the

machine is in local mode.
As an example, should 0-100% output control be required at the wirefeeder, the power source should

be set to local mode, and both the amps (wirespeed) and volts controls set to 100% (maximum). the

wirefeeder will then be able to control between 0-100% of output [both amps(wire speed) and volts].
Should 50% output be required at the wirefeeder controls, the power source should be set to local

mode, and both the amps (wirespeed) and volts set to 50% (mid point). The wirefeeder will then

be able to control between 0-50% of output [both amps(wirespeed and volts)]

NOTE

When a 19 pin wirefeeder in used, 100% output for both amps (wirespeed) and volts is available

at the wirefeeder at all times regardless of the amps (wirespeed) and volts control settings at the

power source (The power source display will show a series of dashes when in 19 pin remote mode).

The wirefeeder can adjust both amps (wirespeed) and volts between 0-100%.

NOTE

Welding Setup Program Storage (10 programs) applies to Mig 10 pin only, Stick and Lift Tig modes.

Advertising
This manual is related to the following products: